ONLY FOR NON DUCTED (recirculating) VERSION
(Using Recirculating Kit model KIT01938)
Air deflector installation
1. Assemble the air deflector with the upper horizontal support
with 2 assembly screws.
B
A. Air deflector
B. Assembly screws
2. Measure from the bottom of the air deflector to the bottom of
the hood outlet, as shown.
A. Dimension to mesure
3. Cut the duct at the measured size.
4. Slip the duct onto the bottom of the deflector.
5. Place the duct over the exhaust outlet from the hood.
6. Use duct tape to seal the deflector and at the exhaust
outlet from the hood.
To place charcoal filter:
1.
Remove metal grease filter from range hood.
See "Metal Grease Filter" in this section.
2.
Bend spring clips away from metal grease filter.
3.
Place charcoal filter into top side of metal filter.
4.
Bend spring clips back into place to secure the charcoal
filter to the metal filter.
5.
Replace metal grease filter.
A
Electrical Connection
WARNING: To reduce the risk of fire, use only metal duct work.
Electrical shock hazard.
Turn off power circuit at the service panel before wiring this unit.
120 Vac, 15 or 20 amp circuit required.
1.
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
A
8
⁄
" strain relief.
1
2
A
B
A. Knockout
B. Terminal box cover