• Auto Stand-By - If there is no operation during the preset time,
the unit enters Stand-by mode. If the work indicator is on before
entering Standby mode, the work indicator will flash in Stand-by
mode
• Auto Power - If there is no operation during the preset time, the
unit will power off automatically
Note: Auto Stand-by and Auto power-off cannot be performed
while WiFi is connected
Indication settings
• Charging indication - In the charging state, you can turn the
charging indicator on or off
• Working indication - In the normal working state, you can turn
the working indicator on or off
General settings
• Time style - Select 12-hour or 24-hour style
• Date style - Choose different date styles according to your pref-
erence
• Time setup - Adjust the current date and time
Watermark Settings
• Users can choose the display style of any watermark on the
screen
Language Settings
• Language choices include German / English / Italian / French /
Spanish
Memory Card Formatting
• Allows the user to format and empty onboard storage
Restore Default
• This function restores the factory settings
Charging
When using the thermal imager for the first time, use the USB
charger to charge the internal battery for at least four hours.
When charging, insert the matching Type C USB charging cable
and plug into power.
• Charging specifications: 5V, 2A.
• Charging indicator is red during normal charging.
• Charging indicator is green when charging is complete.
• Do not charge the battery in an environment over
40˚C or 104˚ F.
Note - Charging when the thermal imager is being used
does not charge the battery. This icon indicates the unit is
using the external power for normal operations.
This icon indicates that the external power supply is
charging the battery
16
Video output
There is a video output port beside the USB interface on the side
of the thermal imager .
The screen image of the thermal imager can be output to an ex-
ternal monitor through the matching HDMI video cable . There are
two display modes, either the external screen or the screen of the
device, but only one mode is active .
Note - When HDMI is used to connect the external display
screen, the real-time screen can only be viewed via the external
display. When the HDMI cable is unplugged, the internal screen
of the device is restored.

STORAGE AND MAINTENANCE

When the thermal imager will be not used for a long time, store
in a dry, well-ventilated environment and charge the unit at least
four hours every two months during the storage
The infrared lens of the thermal imager is coated with an anti-re-
flection film . Clean the lens only when dirt or smudges are pres-
ent . Frequent scrubbing may damage the lens coating .
To clean non-optical surfaces of the thermal imager, do not scrub
with chemical solvents or cleaners . On exterior surfaces, wipe with
a soft and dry microfiber cloth .
WARRANTY
The Nighthunter H35 thermal products are covered by the Steiner
2 year warranty and Steiner will repair or replace your product if
it is defective . Do not disassemble the thermal imager as this will
void the warranty . Contact your nearest Steiner dealer for assis-
tance .