Resumen de contenidos para Geyser GF47-S

  • Página 1 GF47-S Stainless Steel Wall Mount Potfiller Kitchen Faucet...
  • Página 2: Tabla De Contenido

    Contents Prior to Installation ............Faucet Specifications ............Parts List ................Pre-Installation ..............Faucet Installation ............Replacement Parts ............14 Care and Maintenance ..........14 Troubleshooting ..............15 Cartridge Replacement ..........16...
  • Página 3: Prior To Installation

    Prior to Installation: • Make sure you have all the necessary parts and tools. • Compatible with 1/2” NPT cold water supply line. • Requires 1 1/4” diameter wall hole opening. • Installation onto a 2x4 backing is recommended. • Asegúrese de tener todas las piezas y herramientas necesarias.
  • Página 4: Faucet Specifications

    Faucet Specifications GF47-S Geyser GF47-S Geyser Stainless Steel Pot ller Faucet 7¾” 10½” Max Height: 10½” Max Length: 22½” Max Spout Reach: 20 ¼“ Pipe Diameter: 1” 2¾” 8¾” 11½” 22½”...
  • Página 5: Parts List

    Parts List 1. Faucet Body Cuerpo del grifo 2. Rubber Gasket Junta de goma 3. Escutcheon Cover Plate Placa de Cubierta del Escudo 4. Mounting Plate Placa de montaje 5. Screws & Wall Anchors x4 Tornillos y anclajes de pared x4 6.
  • Página 6: Pre-Installation

    Pre-installation: Using a 2x4 Optional, recommended backing Installation onto a 2x4 backing is recommended, but not required for installation. 2x4 should be flush with studs against the drywall. Pass the 1/2” NPT supply line through the 2x4. Faucet will mount onto 2x4. Se recomienda la instalación en un soporte de 2 x 4, pero no es necesario para la instalación.
  • Página 7: Faucet Installation

    Faucet Installation Instalación de Grifo Step 1 Slide the mounting plate (4) onto faucet shank. Deslice la placa de montaje (4) en el vástago del grifo. Step 2 Thread the faucet body (1) onto the supply pipe. Slide the mounting plate (4) to be flush with the wall.
  • Página 8 Faucet Installation continued Step 3 Mark the four screw locations on the wall. Marque las cuatro ubicaciones de los tornillos en la pared. Step 4 Remove faucet from pipe, remove mounting plate from faucet. Retire el grifo del tubo, retire la placa de montaje del grifo.
  • Página 9 Faucet Installation Step 5 5A: If there is no 2x4 backing, use included anchors. Drill 5/16” holes at marked points, then insert anchors by lightly hammering until flush. 5B: If attaching to 2x4 backing behind wall, drill 1/8” holes at marked points. 5A: Si no hay respaldo 2x4, utilice los anclajes 5A (optional) incluidos.
  • Página 10 Faucet Installation continued Step 7 Position the gasket (2), then mounting plate (4) over the holes, ensuring the set screw is down. Secure the gasket and mounting plate to the wall with the screws. Coloque la junta (2), luego la placa de montaje (4) sobre los orificios, asegurando que el tornillo de ajuste esté...
  • Página 11 Faucet Installation continued Step 9 Use a strap wrench to secure the faucet body onto the supply pipe. The entire faucet body will turn clockwise, be sure to tighten until the faucet is fully threaded and upright in its desired final position.
  • Página 12 Faucet Installation continued Step 11 Slide the cover plate to be flush with the wall, then use a H1.5 hex wrench (6) to tighten the set screw on the bottom of the escutcheon cover plate (3) to fasten it to the mounting plate. Deslice la placa de cubierta para que quede a ras con la pared, luego utilice una llave hexagonal H1.5 (6) para apretar el tornillo de ajuste en la...
  • Página 13 Faucet Installation continued Step 13 Remove the aerator, using an adjustable wrench. Remove the washer. Turn the faucet on for 1 minute to flush any debris from the line and faucet. Turn off the faucet and reinstall the aerator. Hand thread it first to prevent cross- threading, then tighten fully with adjustable wrench.
  • Página 14: Replacement Parts

    Replacement Parts Piezas de repuesto 190006203 Rubber Washer 190004165 Neoperl Aerator 190004858 Aerator Nozzle Ring 190006780 Cover 190009322 Screw 190009056 190001453 190006345 Cartridge Adaptor Handle 190001457 190006176 Ceramic Cartridge 190009215 190001035 Rubber Gasket Screws 190009216 Mounting Plate Cartridge Cover Escutcheon Cover Plate Care and Maintenance •...
  • Página 15: Troubleshooting

    Troubleshooting Solución de problemas In the unlikely event that you encounter problems during installation or during the lifetime of the faucet, try these easy fixes to restore your faucet to full working order. En el improbable caso de que tenga problemas durante la instalación o durante la vida útil de la llave, pruebe estas soluciones sencillas para restaurar el grifo a su orden de funcionamiento completo.
  • Página 16: Cartridge Replacement

    Cartridge Replacement del cartucho Reemplazo Tools Required: H2.5 Hex Wrench, Herramientas necesarias: H2.5 llave hexagonal, Llave ajustable, destornillador Phillips # 2 Adjustable Wrench, #2 Phillips Screwdriver Step 1 Shut off the water supply line. Loosen and remove the handle by hand. Remove the endcap.
  • Página 17 Cartridge Replacement continued Step 3 Grasp the protruding end of the ceramic cartridge with adjustable wrench or pliers and pull firmly to remove it from the faucet body. Sujete el extremo sobresaliente del cartucho de cerámica con una llave ajustable o alicates y tire con firmeza para sacarlo del cuerpo del grifo.