Replacement Parts; Disposal Note - Grohe 39438000 Manual Del Usuario

Ocultar thumbs Ver también para 39438000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
Caution with allergy!
Magnet contains nickel und NdFeB.
Caution with pacemakers
People with pacemakers must keep sufficient
distance to magnets (min. 300mm)
Caution caused by magnetic field
Keep magnet away from electrical devices and
objects, which can be damaged by magnetic fields.
The safety data sheets for the product can be downloaded
from www.grohe.com/safety-data-sheets/
Activating cleaning mode,
see page 2.
Triggering flushing and signalling status,
see page 2.
*F: Remaining battery capacity
*G: Solenoid valve intact / defective
*H: Temperature sensor intact / defective
Making settings
, see page 3 and 4
Demounting ceramic and shut off water supply,
see Fig. [1].
Activating setting mode, see Fig [2].
Setting the flow volume, see Fig. [3a] .
Setting the programme, see Fig. [3b].
Observe programme table, see fold-out page I.
Assamble in reverse order, see Fig. [4].
Setting mode is automatically terminated after 3 minutes.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• Battery discharged
(Electronics signaled beeps)
• Outlet clogged
• Temperature sensor defective
• Through high ambient temperature, the
water temperature in the siphon and in the
water supply is > 35 °C
• Flushing during continuous use is activated
(Flushing is initiated every 8 min.
independent of the use)
Undesired water
• Automatic flushing activated
flow
• Through high ambient temperature, the
water temperature in the siphon is > 35 ° C
• Solenoid valve defective
Flow volume too
• Solenoid valve defective
low
• Filter in solenoid valve blocked
Maintenance
Demounting ceramic and shut off water supply,
see page 3, Fig. [1].
Inspect and clean all components and replace if necessary.
I. Batterie, see page 5, Fig. [1] and [2].
A required change will be signaled by beeps of the electronic.
II. Solenoid valve and filter, see page 5, Fig. [3] and [4].
III. Siphon with temperature sensor, see page 5, Fig. [5].
IV. Electronic, see page 5, Fig. [6].
Assamble in reverse order.

Replacement parts

see fold-out page I

Disposal note

This category of device does not belong in the
domestic waste, but must be disposed of separately
in accordance with the relevant national regulations.
Dispose of batteries in accordance with national
regulations.
Remedy
- Open shut-off valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Clean outlet
- Replace siphon with temperature sensor
- Ensure operating temperature of the water in the
water supply
- After drop of the temperature in the siphon the
elektronic terminates the mode flushing during
continuous use automatically
- The elektronic triggers a flushing to reduce the
water temperature in the siphon
- Replace solenoid valve
- Replace solenoid valve
- Clean filter
8