I. Cartridge, see fold-out page III, Fig [13].
Assemble in reverse order. When installing the cartridge,
ensure that the seals are correctly seated. Replace screw
coupling and tighten.
II. Headpart, see fold-out page III, Fig. [14].
Assemble in reverse order. Note the installation position of the
stop.
III. Diverter, see fold-out page III Fig. [15].
Assemble in reverse order.
IV. Mousseur (48 196), see fold-out page I.
Assemble in reverse order.
V. Solenoid valve (42 390), see fold-out page I.
Assemble in reverse order.
VI. Non-return valve (08 565), see fold-out page I.
Assemble in reverse order.
Fault
Cause
Water not flowing
• Water supply interrupted
• Solenoid valve defective
• Plug-in connector of solenoid valve
without contact
Filtered water not
• Water supply interrupted
flowing
Filtered water is
• Safety shut-off of solenoid valve for
interrupted, E2
running time of over 4 minutes
flashes in the display
No filtered water, E3
• No connection between fitting and
in the display
cooler/carbonator
• Cable or connector faulty
No filtered water,
• Fitting and control unit not synchronized
®
Blue
handle flashes
red, E4 in the display
No filtered water,
• Values range does not concur
®
Blue
handle flashes
red, E6 in the display
• Filter capacity exceeded
®
Blue
handle flashes
orange, E7, E8 in the
display
Indicator lamps
• Control not recognised
do not flash/flash
continuously
Display in handle
• No connection between fitting
does not illuminate
and control unit
or illuminates
continuously
Service
Note the Fault / Cause / Remedy table for information on
eliminating problems.
If EE flashes or the problem cannot be rectified, interrupt the
power supply and consult a specialist installer or contact the
GROHE Service Hotline via email under TechnicalSupport-
HQ@grohe.com.
Replacement parts
See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Environment and recycling
Used filter cartridges can be disposed of hazard-free in
domestic waste.
Remedy
- Open shut-off valves
- Replace solenoid valve
- Attach plug-in connector
- Establish water supply to fitting
- Close handle and open it again.
- Connect plug-in connector
- Contact GROHE Service
- Synchronise with one another, see section
Installation
- Synchronise with one another, see section
Installation
- Change filter cartridge immediately
- With mains plug connected, disconnect plug-in
connector, wait 30 seconds and reconnect
- Synchronise with one another, see section
Installation
6