Adjusting The Operating Power And The Working Times; Slowing Down; Transmitter Storage; Rolling Code Mode - V2 ELETTRONICA PRGU433PP Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ADJUSTING THE OPERATING POWER AND THE WORKING TIMES

The operating power and the working times can be adjusted through 4 potentiometers
that are located on the control unit:
POWER:
motor power.
T. WORK: motor working time.
T.PAUS.:
time-out (only when the control unit is programmed to close automatically).
T.DELAY: time elapsing between the openings of leaf 1 and leaf 2.

SLOWING DOWN

At the end of each opening and closing phase the central unit automatically activates a
slowing down phase during which the motors are low speed driven, in order to avoid a
violent collision against the stopping end. Set the working time T.WORK in order to start
the slowing down phase before the gate reach the stopping end.
We suggest, furthermore, to use a time of delay T.DELAY not too high.

TRANSMITTER STORAGE

To correctly memorize the code it is necessary to keep a minimum distance of 1,5 metres
between the transmitter and the receiver's antenna. To program the radio receiver, please
proceed as follows:
• Keep PROG.RX pressed until the led L1 lightens
• Keep the button of the transmitter pressed until the led L1 goes off for about a
1/2 second indicating the correct memorization of the code.
Then the led start immediately flashing for a number of times corresponding to
the number of the memory zone which has just been taken.
• Once the flashings have ceased, the system is ready to be used.
IMPORTANT: every stored code is only associated with the START command.

ROLLING CODE MODE

It is possible to enable and to disable the ROLLING CODE function (normally disabled) ,
that will avoid any risk of Personal Pass code duplication.
• Press PROG.RX push-button, holding it for 8 seconds.
• L1 led will switch off after 8 seconds. Release the push-button.
• L1 led starts a sequence of flashing for 5 seconds:
Single flashings
Double flashings
• To modify the parameters press the PROG.RX
push-button within 5 seconds after the first flashing of the sequence; L1 led will flash
according to the new parameters.
(PRGU433PP - PRGU433PP127)
(PRGU433PP - PRGU433PP127)
ROLLING CODE is disabled
ROLLING CODE is enabled