Master/Slave

Section [2] — Option [7]
Off = Master (default)
On = Slave
Activate this option with control panels using more than 12 zones. If
there are more than 12 zones being used in the system, only one
LCD keypad can be master and all other keypads are slaves. If using
more than 12 zones in the system and more than one keypad is set
as a "master", a display problem will result. All slave LED keypads
must be used in "mute" mode. Any of the keypads connected to the
control panel will be able to display open zones.
Arming Display for Systems that Support >/< 12 zones
Section [2] — Option [8]
Off = Less than 12 zones (728+, 738EX+, 728ULT) (default)
On = More than 12 zones (738+, 748+)
Make sure that this option is set to match the control panel being
used. If the control panel is incompatible with the keypad, there will
be a display problem.

Zone Display

Section [2] — Option [9] and Option [
[9]
[
]
Result
ARM
OFF
OFF
Scrolling Zone Display
OFF
ON
Scrolling Zone Display
ON
OFF
Multiple Zone Display
ON
ON
Scrolling and Multiple Zone Display
Multiple Zone Display shows the status of several zones on a single
screen without zone labels. If zones 3 and 4 were open, the screen
would read: Zones Open 3 4. This screen alternates with the
system status screen.