TO INSTALL:
1. Turn off water at the supply stop(s).
2. Remove existing handles and units. Follow the chart on the
first page (Figure 1 ) to insure that the correct parts are being
used.
3. Flush supply lines to remove chips and dirt which can
become lodged in the seat washer and cause the faucet to
run on.
4. Inspect the seating surface inside the body and clean
thoroughly. If the seat is damaged (pitted or nicked) or if
heavy lime build-up has occurred, contact your nearest
Chicago Faucet representative for assistance. Failure to clean
up old seating surfaces can damage the new MVP™
cartridge and cause a dripping or
run-on situation. (Figure 2)
TROUBLE SHOOTING:
Accumulation of lime and/or dirt in
the cartridge can result in either short
or excessively long cycles. If either
occurs, remove cartridge and wash
with soap and water or a mild
solution of vinegar and water. If
continued problems are experienced,
contact your local representative for assistance.
5. Insert the filter into the body and make sure it is completely
down and in place against the body seat. Then insert the
cartridge into the body. Make sure the cartridge is also
completely down and in place against the body seat
(Figure 3).
INSPECT
SEATING
AREA
FIGURE 2
TYPICAL
BODY
3