Description
This submersible pump is designed to
supply water at the required pressure
with high efficiency and a long service
life. To maximize pump life, care must
be taken in its installation and usage.
Unpacking
After unpacking the submersible pump,
carefully inspect for any damage that
may have occurred during transit.
Check for loose, missing or damaged
parts.
Safety Guidelines
This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important infor-
mation, that if not followed, may cause
damage to equipment.
General Safety
Information
1. Read the instruction manual included
with the product carefully. Be thor-
oughly familiar with the controls and
the proper use of the equipment.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2007 Blue Angel™ Pumps
Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Deep Well Submersible Pumps
2. Know the pump application, limita-
tions and potential hazards.
sive fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in explosive
atmospheres. Pump should only be used
with liquids compatible with pump com-
ponent materials. Failure to follow this
warning can result in personal injury
and/or property damage.
sure from the system before attempting
to install, service, relocate or perform any
maintenance. Lock the power disconnect
in the open position. Tag the power dis-
connect to prevent unexpected applica-
tion of power.
3. Personal Safety:
a.
Wear safety glasses at all times
when working with pumps.
b. Keep work area clean, unclut-
tered and properly lit.
c.
Keep visitors at a safe distance
from work area.
4. Do not pump chemicals or corrosive
liquids. Pumping these liquids short-
ens the life of the pumps seals and
moving parts and will void war-
ranty.
5. When installing pump, prevent for-
eign matter from falling into well,
contaminating the water and dam-
aging internal mechanical compo-
nents.
6. Always test the water from the well
for purity before use. Check with
local health department for test
procedure.
7. Do not run the pump dry or damage
will occur and will void warranty.
licensed or certified electrician.
8. For maximum safety, the unit
should be connected to a grounded
circuit equipped with a ground
For parts, product & service information
visit www.blueangelpumps.com
TB50S10-2, TB50S10-4, TB75S10-2,
TB75S10-4, TB100S10-2, TB51S10-4
Do not use to pump
9. Before installing the pump, have
flammable or explo-
10. Make sure the line voltage and fre-
Disconnect power
and release all pres-
11. Do not attempt repairs to the elec-
12. Avoid kinking electrical cord and
nect the green wire (or green and yellow
wire) to a live terminal!
13. Use only 3-wire extension cords
14. Use wire of adequate size to mini-
15. Pipe joint compound can cause
motor with wet hands, when standing
on a wet or damp surface or when
standing in water. Fatal electrical
All wiring should be
shock could occur.
performed by a
automatic resetting thermal protector
fault circuit interrupter (GFCI)
device.
the electrical outlet checked by a
licensed or certified electrician to
make sure the outlet is properly
grounded.
quency of electrical current supply
agrees with the motor wiring.
tric motor. All repairs to the motor
must be completed at a licensed or
certified electrical motor repair
shop.
protect electrical cord from sharp
objects, hot surfaces, oil and chemi-
cals. Replace or repair damaged or
worn cords immediately.
Risk of electric
shock! Never con-
that have a 3-prong, ground type
plug, and 3-pole receptacles that
accept the equipment plug.
mize voltage drop at the motor.
cracking in plastics. Use only
®
Teflon
tape when sealing joints in
plastic pipe or when connecting
pipe to thermoplastic pumps.
Do not handle
pump or pump
Pump motor is
equipped with an
340601-002 1/07

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Blue Angel Pumps TB50S10-2

  • Página 1 TB50S10-2, TB50S10-4, TB75S10-2, Operating Instructions and Parts Manual TB75S10-4, TB100S10-2, TB51S10-4 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Página 2: General Safety Information

    Deep Well Submersible Pump Operating Instructions and Parts Manual NOTE: See Installation Wiring General Safety 2. Motor is supplied with copper Diagrams for typical wiring hookups grounding wire. Splice wire to cop- Information (Cont.) and control box identification. per conductor that matches wire and may restart unexpectedly.
  • Página 3 1 phase, 2 or 3 wire cable, 60 Hz (copper wire size—service to motor) Electrical System Voltage Wires Pump Model No. Control Box No. (Cont.) TB50S10-2 16965-002 Single Phase, 2 Wire TB50S10-2 None Two-wire pumps have two power sup- TB51S10-4 None ply wires and one ground wire (Green).
  • Página 4 Operating Instructions and Parts Manual Deep Well Submersible Pump Installation 1. With wire cutting tool, cut off POWER SUPPLY WIRE INSTALLATION motor leads. Stagger lead and wire 1. To test pump, connect it to proper WIRE SPLICING length so that second lead is 4" power supply for a short amount of Splice wire to motor leads.
  • Página 5 Operating Instructions and Parts Manual Deep Well Submersible Pump CONNECTING TO TANK/WATER Installation (Cont.) SYSTEM other end of safety rope securely to well seal, well cap or pitless adapter. NOTE: Discharge outlet is 1-1/2" NPT High pressure and tank explosion haz- ard! To prevent overpressurization, threaded.
  • Página 6: Troubleshooting Chart

    Deep Well Submersible Pump Operating Instructions and Parts Manual charged pressure should be 28 psi [193.1 kPa].) Adjust pressure by adding or releasing air from the tire valve located on top of tank. Check pre- charged pressure annually and adjust as needed.
  • Página 7 Deep Well Submersible Pump Operating Instructions and Parts Manual Troubleshooting Chart (Cont.) Symptom Possible Cause(s) Corrective Action 1. Leaks in system Pump starts too fre- 1. Check tank connections with soapy water. Check plumb- quently ing for leaks. Ensure system is airtight and watertight. 2.
  • Página 8 Operating Instructions and Parts Manual Deep Well Submersible Pump Limited Warranty For one year from the date of purchase, Blue Angel™ will repair or re place, at its option, for the original purchaser any part Deep Well Submersible Pump or parts of (“Product”) found upon examination by Blue Angel™...
  • Página 9 TB50S10-2, TB50S10-4, TB75S10-2, Manual de instrucciones de funcionamiento y piezas de repuesto TB75S10-4, TB100S10-2, TB51S10-4 Sírvase leer y conservar estas instrucciones. Léalas con cuidado antes de intentar armar, instalar, operar o efectuar mantenimiento al producto descrito. Protéjase a sí mismo y a los demás observando la información de seguridad.
  • Página 10: Preinstalación

    Bomba sumergible para pozos profundos Manual de instrucciones de funcionamiento y piezas de repuesto Información general y al largo del recorrido del cable). Conecte la bomba a tierra permanente- mente, así como también el motor y la NOTA: Vea los Diagramas de cableado de seguridad caja de control antes de conectar al (Cont.)
  • Página 11: Instalación

    Monofásico, cable de 2 ó 3 alambres, 60 Hz (calibre del cable de cobre – trabajo al motor) Sistema eléctrico Voltaje Cables Nº de modelo de bomba N° de caja de control (Cont.) TB50S10-2 16965-002 energía (rojo/negro/amarillo) y un TB50S10-2 Nada cable de conexión a tierra (verde).
  • Página 12 Manual de instrucciones de funcionamiento y piezas de repuesto Bomba sumergible para pozos profundos Instalación (Cont.) 3. Haga coincidir los colores de los cables de la fuente de energía con los colores de los tomas del motor. 4. Introduzca los extremos de los cables de la fuente y de los tomas en los Figure 5 - Listo para empalmar conectores de tope y empuje (ver...
  • Página 13 Manual de instrucciones de funcionamiento y piezas de repuesto Bomba sumergible para pozos profundos Instalación (Cont.) Figura 8 – Conexiones temporales mientras se limpia el pozo para el encendido Figura 9 - Instalación típica de un tanque precargado 13 Sp...
  • Página 14: Guía De Diagnóstico De Averías

    Manual de instrucciones de funcionamiento y piezas de repuesto Bomba sumergible para pozos profundos Figura 10 - Instalación típica de un tanque estándar Guía de diagnóstico de averías Síntoma Causa(s) posible(s) Acciones a tomar El motor no arranca, pero 1. No hay voltaje en la caja de con- 1.
  • Página 15 Manual de instrucciones de funcionamiento y piezas de repuesto Bomba sumergible para pozos profundos Guía de diagnóstico de averías (Cont.) Síntoma Causas(s) posible(s) Acciones a tomar 1. Voltaje bajo o alto Los fusibles están quema- 1. Si la variación de voltaje es mayor que el 10% de la clasificación dos o el protector de de la placa, llame a la compañía eléctrica para ajustar el voltaje.
  • Página 16: Garantía Limitada

    Bomba sumergible para pozos profundos Manual de instrucciones de funcionamiento y piezas de repuesto Garantía Limitada Durante un año a partir de la fecha de compra, Blue Angel™ reparará o reemplazará para el comprador original, según lo que decida, cualquier pieza o piezas de su bomba sumergible para pozos profundos ("Producto") que después de un examen Blue Angel™...

Este manual también es adecuado para:

Tb50s10-4Tb75s10-2Tb75s10-4Tb100s10-2Tb51s10-4

Tabla de contenido