See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions and Replacement Parts List
Description
The BSP25 is a battery operated back-
up sump pump. It does not replace a
regular pump. It is designed to provide
protection in the event household
electrical power fails.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information that is
very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
an imminently hazardous situation
which, if not avoided, will result in
death or serious injury.
a potentially hazardous situation
which, if not avoided, COULD result in
death or serious injury.
a potentially hazardous situation
which, if not avoided, MAY result in
minor or moderate injury.
important information, that if not
followed, may cause damage to
equipment.
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2008 Blue Angel ™ Pumps
Please read and save these instructions. Read carefully before attempting to assemble, install, operate
or maintain the product described. Protect yourself and others by observing all safety information.
Failure to comply with instructions could result in personal injury and/or property damage! Retain
instructions for future reference.
12 Volt Backup
Sump Pump
General Safety
Information
CALIFORNIA PROPOSITION 65
or its power cord contains chemicals
known to the State of California to
cause cancer and birth defects or other
reproductive harm. Wash hands after
handling.
GENERAL
Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in a
flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Fatal injury and/or
property damage could result.
If the basement has water or
moisture on the floor, do not
walk on wet area until all
power is turned off. If the shutoff box
is in the basement, call an electrician.
Remove pump and either repair or
Danger
replace. Failure to follow this warning
indicates
could result in fatal electrical shock.
must be performed by a qualified
Warning
electrician.
indicates
Do not expose battery to
sparks or flames as an
Caution
explosion or fire could result.
indicates
Battery acid is corrosive.
Avoid spilling on skin or
Notice
clothing. Eye protection must
indicates
be worn when handling the battery.
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.blueangelpumps.com
must be used on the primary sump
pump discharge.
This
product
fault circuit interrupter is required.
must only be used to pump clear water.
This pump is not designed to handle
effluent, salt water, brine, laundry
discharge or any other application
which may contain caustic chemicals
and/or foreign materials. Pump damage
may occur if used in these applications
and will void warranty.
Battery Information
The system is designed to operate most
efficiently with sealed lead acid (SLA)
batteries. Deep cycle marine batteries
or automotive style batteries can also
be used.
Sealed lead acid batteries cost slightly
more, but they can last longer. Among
the manufacturers of sealed lead acid
batteries are Hawker, Panasonic,
PowerSonic, Yuasa and Eagle Picher.
All
The oversize battery case (included) will
wiring
accommodate a 12-volt SLA battery or
a 12-volt deep cycle marine battery (up
to a 27-frame size).
Be certain that the area around the
batteries is well ventilated. Before
servicing the batteries, blow away
gasses by waving a piece of cardboard
near the batteries.
BSP25
A check
valve
A ground
This
pump
352205-002 3/08

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Blue Angel Pumps BSP25

  • Página 1 Description General Safety A check valve Information The BSP25 is a battery operated back- must be used on the primary sump pump discharge. up sump pump. It does not replace a CALIFORNIA PROPOSITION 65 regular pump. It is designed to provide...
  • Página 2: Battery Information

    2. This pump has a 1-1/2 inch NPT Working discharge. If a 1-1/4 inch discharge in the vicinity of lead acid batteries can The BSP25 can be installed as a back up be dangerous. Before making pipe is desired, an adapter (not system with a separate dedicated connections or servicing the batteries, included) will be necessary.
  • Página 3 Check Valve Check valves will be required. (See Step 10) Valve 1. Locate the BSP25 on a solid, level (See surface in the sump pit. Do not Step 10) place the pump on a loose or sandy surface. Small stones or sand may...
  • Página 4 Operating Instructions and Replacement Parts List Installation 5. Protect electrical cord from sharp a. After main AC pump and objects, hot surfaces, oil and charger are unplugged, a power off (Continued) chemicals. Avoid kinking the cord alert tone will sound for 30 and replace damaged components seconds.
  • Página 5 BSP25 Maintenance 4. Unplug the main pump and fill sump with water until back up If battery acid contacts your eye(s), pump turns on. Repeat process two flush with cold running water for 10 times to be sure pump is operating...
  • Página 6: Troubleshooting Chart

    Operating Instructions and Replacement Parts List Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump won’t run 1. Connections not secure 1. Check all connections 2. Low or defective battery 2. Check battery and replace if low or defective 3. Float switch stuck 3.
  • Página 7 For Replacement Parts, call 1-888-636-6628 Please provide following information: Address parts correspondence to: - Model number Blue Angel Pumps - Serial number (if any) 101 Production Drive - Part descriptions and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Página 8 Limited Warranty For two years from the date of purchase, Blue Angel Pumps (“Blue Angel”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel to be defective in materials or workmanship.
  • Página 9 12 volts Description Avis indique Le modèle BSP25 est une pompe de L’acide de pile est corrosive. de l’information importante pour Ne pas le renverser sur la puisard de sauvegarde actionnée par éviter le dommage de l’équipement.
  • Página 10 Méthode 1 (de choix) Du gaz le démontage de la pompe principale. d’hydrogène peut être dégagé des 1. Placer la BSP25 sur une surface batteries en chargeant. Des étincelles 1. Couper la puissance à la pompe peuvent enflammer le gaz dans un solide, à...
  • Página 11 BSP25 Montage 1. Placer la BSP25 sur une surface Fixer une section de 3,2 cm (Suite) solide et à niveau dans le puisard. (1-1/4 po) de tuyau à l’adaptateur 3. Couper une section de 1,2 m (4 pi) Ne pas placer la pompe sur une de décharge BSP25.
  • Página 12 Fond de la boîte de pile de contrôle 9. Coller un coude de 45º au tuyau Fils de plomb court de la pompe BSP25. Coller un Toujours débrancher la source raccord en ‘Y’ au tuyau court sur la de puissance avant d’essayer pompe actuelle, tel qu’indiqué...
  • Página 13 BSP25 Fonctionnement Entretien BATTERIES (Suite) Du gaz d’hydrogène peut être dégagé des a. Après avoir débranché la pompe Toujours débrancher la source batteries en chargeant. Des étincelles c.a. principale et le chargeur, une d’électricité avant d’essayer peuvent enflammer le gaz dans un d’installer, de déplacer ou de...
  • Página 14: Guide De Dépannage

    Instructions d’Utilisation et Manuel de Pièces Guide de Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Pompe ne 1. Raccords ne sont pas sûrs 1. Vérifier tous les raccords fonctionne pas 2. Batterie faible ou défectueuse 2. Vérifier la batterie et la remplacer si faible ou défectueuse 3.
  • Página 15 Pour pièces de rechange, composer 1-888-636-6628 S’il vous plaît fournir l’information suivante: Correspondance: - Numéro du Modèle Blue Angel Pumps - Numéro de Série (si présent) 101 Production Drive - Description et numéro de la pièce Harrison, OH 45030 U.S.A.
  • Página 16: Garantie Limitée

    Garantie Limitée Pendant deux ans à compter de la date d’achat, Blue Angel Pumps ("Blue Angel") va réparer ou remplacer, à sa discrétion, pour l’acheteur original toute pièce ou pièces de ces Pompes De Puisard ou Pompes À Eau ("Produit") déterminées défectueuses, par Blue Angel, soit pour les matériaux ou la fabrication.
  • Página 17: Descripción

    Descripción Ésto le Todas indica La BSP25 es una bomba auxiliar para las conex-iones de cables deben ser una información importante, que de no realizadas por un electricista calificado. sumideros que funciona con batería. seguirla, le podría ocasionar daños al equipo.
  • Página 18: Información Sobre La Batería

    (SLA). También pueden usarse baterías Instalación de la bomba agua y jabón. marinas de ciclo profundo y de tipo La BSP25 puede instalarse como un automotriz. Nunca sistema de respaldo con una línea de fume ni Las baterías selladas de plomo-ácido...
  • Página 19 Método 1 (se prefiere) tubería de descarga hacia una pared 2. Esta bomba tiene una descarga de 1. Coloque la BSP25 sobre una exterior, por el camino más corto, 1-1/2 pulg. NPT (3,8 cm). Si se desea superficie sólida y nivelada en el siguiendo las técnicas de instalación...
  • Página 20: Funcionamiento

    9. Pegue un codo de 45º al tubo corto Si los cables se cuando el nivel del agua sea en la bomba BSP25. Pegue un conectan al revés, puede dañarse la caja superior a la profundidad en la que adaptador en “Y” al tubo corto en de control o la batería, y la garantía...
  • Página 21: Mantenimiento

    BSP25 Funcionamiento Mantenimiento BATERÍAS Mientras (Continuación) se están cargando, las baterías pueden liberar a. Después de haber desconectado Siempre desconecte el gas hidrógeno peligroso. Las chispas la bomba de CA principal y el suministro eléctrico antes de pueden hacer que el gas entre en cargador, sonará...
  • Página 22: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Piezas Guía de diagnóstico de averías Problema Posible(s) Causa(s) Acción Correctiva La bomba no 1. Conexiones flojas 1. Revise todas las conexiones funciona 2. Batería baja o defectuosa 2. Revise la batería y reemplácela si está baja o defectuosa 3.
  • Página 23 Sírvase proporcionar la siguiente información: Escribanos a la siguiente dirección: - Número del modelo Blue Angel Pumps - Número de serie (de haberlo) 101 Production Drive - Descripciones y número de piezas, tal como aparecen en la lista de piezas.
  • Página 24: Garantía Limitada

    Garantía Limitada Durante dos años a partir de la fecha de compra, Blue Angel Pumps ("Blue Angel") reparará o reemplazará para el comprador original, según lo que decida, cualquier pieza o piezas de su Bombas de resumideros, Bombas de agua ("Producto") que después de un examen Blue Angel encuentre que tenían defectos en su material o mano de obra.

Tabla de contenido