Idiomas disponibles

The vibrating pump.
The engine operates
intermittently or winding
motor burnt.
Mechanical seal leak
Abnormal pump noise.
The switch does not work
or pressure starts-stops
too frequently

8. Disposal and recycling machine

Get rid of your appliance in an ecological way. We should not get rid of the
machines together with household garbage. Plastic components and metal can be
classified according to their nature and reciclarse.Los packaging materials used this
machine are recyclable. Please do not throw packaging in the household rubbish.
Pull these packages in an official waste collection point.

9. Warranty conditions

- The warranty period (1999-1944 CE Act) under the terms described below is 2 years from the
date of purchase on parts and labor against defects in workmanship and material.
The warranty does not cover in any case: - Natural wear and tear.
- misuse, neglect, careless operation or lack of Maintenance.- Defects caused by misuse,
damage due to manipulations by unauthorized personnel by Anova or use of non-original spare
parts.
The inlet pipe, screen filter or pump
chamber are blocked by foreign
materials.
The pump is fixed on the base.
Debris in the pipe or the pump
chamber.
The base is not stable enough.
The engine is overloaded operation
for a long time.
The impeller is jammed or
overloaded for a long time.
Improper grounding, broken wire or
electric pump has been struck by
lightning.
The mechanical seal is worn and torn
by impurities.
Bearing noise.
The impeller is jammed.
Delivery head inappropriate and
excessive.
The pressure is too low within the
tank.
The pressure is too high within the
tank.
Clean pipe, the foot valve or the pump
chamber, clean debris.
Tighten the bolt base.
Check and clean the pipe and the pump
body.
Set the pump to the stable base.
Install the valve in the output, reduce water
yield.
Clean debris in the pump chamber; Operate
the pump below the nominal flow as much as
possible.
Look for the reason and replace the coils of
the motor. Check with your service center.
Clean or replace the mechanical seal.
Replace with the same type of bearing.
Remove debris and dirt.
Set to the range shown on the nameplate
before use.
Check and adjust the pressure between 1.4-
1.6bar
- -