See WARNING and Figures:
WARNING
This screen must be clear and free of
obstructions at all times to insure proper
operation.
WARNING
The burner of the firebowl must be covered by
lava rocks completely. Otherwise the flame
may be extinguished. See the Figure for
the CORRECT and INCORRECT ways
for reference.
Perform leak test in a well-ventilated area outside and where no source of spark can occur.
Remove battery from igniter. Open tank valve fully (counter-clockwise). Turn the on/off valve at the unit to the "OFF" position to
pressurize the hose assembly. Use a soapy water solution to check all the connections f or leaks before attempting to light the appliance.
If a leak is found, turn the tank valve off and do not use the appliance until repairs can be made.
TIPS:
Before Starting
TO LIGHT
Before each use, inspect the hose. Replace hose if there are any signs of cutting, wear or abrasion.
(1) Turn the cylinder valve on the gas tank counter-clockwise to open the gas supply.
(2) Close the storing door on the firebowl for the gas tank.
(3) Light the firebowl as below in the following image:
A. Press and hold the Electric Ignitor. Meanwhile, push and turn the control knob counter-clockwise to the 'LOW'
position. Keep pushing the control knob to light the burner.
B. After ignition, release the Electric Ignitor. Continue to push and hold the control knob for 45 seconds.
C. If ignition does NOT immediately take place in seconds, push and turn the control knob clockwise to 'OFF'. Wait 5
minutes, and then repeat the lighting procedure as above.
Caution: *If the burner does not ignite with the valve open, gas will continue to flow out of the burner and could accidently
ignite with risk of injury.
CORRECT
Read the instructions thoroughly.
•
Check and make sure that all parts are present.
•
For future reference, save this instruction manual.
•
Observe flame height when lit:
Flame should possibly be a yellow/blue color between 2
to 10 inches high.
7
INCORRECT