• If the hoist stops during the load lowering, the load will normally lower a few more millimetres due
to the inertial force.
• Never pull or push laterally the rope or the load.
• Transport of people with the hoist is forbidden.
• Avoid switch-on/switch-off quickly sequences.
• ATTENTION!! THE HOIST ELECTRIC MOTOR IS NOT SUPPLIED WITH ANY OVERLOAD CUT-OUT ( TO
AVOID AN UNEXPECTED RE-START) THEREFORE, IF YOU ARE UNABLE TO HOIST A LOAD DO NOT
INSIST AND LET THE MOTOR COOL DOWN.
• Wear gloves during the transport.
4. INSTALLATION
The hoist "standard version" is provided with a specially designed bracket system which allows to
hold pipes box, sections and rectangular beams.
WARNING! When operating, the device must be perfectly horizontal in order to avoid damaging
the internal organs.
Check that socket features (volt-hertz) correspond to those indicated on the machine plate; then,
you can insert the plug. In case a cable extension is needed, it is absolutely important to respect
the table's data. After using the machine put it in a dry and ventilated place.

5. ROUTINE MAINTENANCE

• Periodically CHECK that the steel cable is in good conditions.
• CHECK that the screws securing the brackets and reduction gear are well tightened.
• Periodically CHECK that motor
conditions.
• For maintenance contact the service center of the company.
VOLTAGE
EXTENSION
VOLT
LENGHT
220÷240
Up to 20 mt
220÷240
from 20 to 50 mt
115
Up to 20 mt
115
from 20 to 50 mt
stop switch and push button panel are in good operating
10
EL. CABLE
SECTION
1,6 mm²
2,5 mm²
2,5 mm²
4 mm²