Please recycle Tripp Lite Products. The batteries used in Tripp Lite products are sealed
lead-acid batteries. These batteries are highly recyclable. Please refer to local codes for
disposal requirements.
Call Tripp Lite for recycling info at 1.773.869.1234.
Go to the Tripp Lite Website for up-to-date information on recycling the batteries or any
Tripp Lite product. Please follow this link: http://www.tripplite.com/support/recycling-program/

Quick Installation

1
Plug the UPS into a properly grounded outlet: After plugging the UPS into a wall outlet, push
the ON/OFF/MUTE/TEST button to turn the UPS on (see Basic Operation section).
Please Note! The UPS will not turn on automatically in the presence of live utility power.
2. Plug your equipment into the UPS: Select outlets (see Basic Operation section) will provide
2
battery backup and surge protection; plug your computer, monitor and other critical devices
here.* Select outlets (see Basic Operation section) will provide surge protection only; plug your
printer and other non-essential devices here.
* Your UPS is designed to support electronic equipment only. You will overload the UPS if the total VA ratings
for all the equipment you connect to the Battery Backup Protected/Surge Protected outlets exceeds the UPS's
Output Capacity. To find your equipment's VA ratings, look on their nameplates. If the equipment is listed in
amps, multiply the number of amps by 120 to determine VA. (Example: 1 amp × 120 = 120 VA). If you are
unsure if you have overloaded the Battery Backup Protected/Surge Protected outlets, run a self-test (see "ON/
OFF/MUTE/TEST" Button description).
Note: UPS system will function properly upon initial startup; however, maximum runtime for the unit's battery
will only be accessible after it has been charged for 24 hours.
If the LINE POWER indicator light does not illuminate when the UPS is turned ON, try the following:
1. Make sure that the UPS is plugged into a live AC outlet.
2. Press the ON/OFF/MUTE/TEST button to start the UPS. (A beep should sound when the UPS starts.)
3. If the UPS still does not start, contact Tripp Lite Tech Support for assistance.