• Connect or replace the power cable fuse.
• Replace electronic control (for access remove the front panel on the air
distribution).
• Check and correct possible bad contacts, breakages or disconnection of the power
cable.
• Connect or replace the electronic control power supply fuse (for access the internal
air distribution panel must be removed).
• Check and correct the position of the connection cables to power supply (Az with
fuse 30A a + and M a -).
!
(If the error persists contact an Authorized Service Centre).
• Check and correct possible bad contacts on terminals or cables of the
return air probe.
• Connect or replace return air probe.
!
(If the error persists contact an Authorized Service Centre).
• Check and correct possible bad contacts on terminals or cables of the
anti-icing probe.
• Connect or replace the anti-icing probe.
!
(If the error persists contact an Authorized Service Centre).