Descargar Imprimir esta página

dirna Bergstrom bycool green COMPACT 1.6 Manual Del Usuario página 20

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

COMPACT 1.6
EN
Symptom
• When turning on device or during
operation, it beeps intermittently,
and when it stops beeping the
display shows Lb (low battery). The
device stops automatically.
• E2 appears on the display, the
device turns off automatically and
the display shows error E2 until
the fault is repaired. To remove
it from the display press the ON/
OFF key once on the keyboard or
the remote control.
• The compressor does not work.
• Bad contact in connections or power
terminals.
• Battery empty or faulty.
• Centrifugal blower or condenser fan
blocked in short circuit or disconnected.
• 7.5A fuse in the centrifugal blower or
condenser fan blown.
• Electronic control faulty.
• Bad connection of the terminals.
• Electronic module on the compressor
faulty.
• Compressor faulty.
• Too much pressure in the circuit due to
excess load or very high temperature.
20
Cause
®

Publicidad

loading