DESCRIPTION
Control Unit for programming and managing the SCM 8000
system.
It is the communications device between the SCM 8000
control unit modules and the PC.
It enables performing the following functions:
o Programming and monitoring of the SCM 8000 control
unit modules from the PC.
o Detection, recording and management of alarms that are
triggered.
o Equipment firmware updates.

INSTALLATION AND SET-UP

- The modules must be connected and disconnected
with the power supply disconnected from the power
source.
Fasten the modules in the rack in the order indicated on
the sample application.
The MCU 8000 unit is installed to the left of the SPS 8000
power supply.
Connect the BA 807 Ref. 83807 power bus between the
modules and the power supply.
Connect the auxiliary cable supplied with the equipment
between the SPS 8000 V test connector and the
MCU 8000 V test connector.
Connect the communications and control buses
(Ref. 83811) between the MCU-8000 and the equipment.
Connect a CU 120 charge to the last module in the set
on the left of the installation.
ADDRESS hub: Each piece of equipment to be controlled
must have a different address.
We recommend using the Address hub in addresses that
increase consecutively from right to left (the first to the left
of the MCU-8000 is address 1, the next is address 2, etc.).
This address corresponds to the image of the control unit
that is seen on the PC.
Connect the power source to the electrical supply.
The control unit will check the equipment belonging to
the control unit. It will communicated with them, adding
them to the database and then track them. The COMM
communications LED will light up in green and blink
when data are being transferred.
FUNCTIONS OF THE MCU 8000 LEDS
Led de estado
Off: no power
STATUS
Green: ok
Red: equipment error or error involving the
power supply connected through V test
COMM communications Off: no communication
LED
Blinking green: communication
ACCESS TO THE CONTROL UNIT
THROUGH THE LOCAL PC
To access the control unit, it is necessary to perform the
following steps:
Install the corresponding PC program for the 8000 Series:
User interface.
Connect the USB B cable to the PC connector on the
MCU 8000 and the USB A connector to the PC.
Once the USB cable is connected, the PC will prompt
the installation of the corresponding driver. Once installed,
the MCU 8000 is recognized and is ready for use.
On the PC program, click on the Connect button to
establish the connection between the PC and the
MCU 8000.
6