On/Off Switch; Drain Valve - DeWalt D55166 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

COMPONENTS AND FEATURES (FIG. A–E)

WARNING: Never modify the power tool or any part
of it. Damage or personal injury could result.
Refer to Figure A at the beginning of this manual for a
complete list of components.
Specifications
MODEL
WEIGHT
HEIGHT
WIDTH
LENGTH
AIR TANK CAPACITY (GALLONS)
APPROX CUT-IN PRESSURE
APPROX CUT-OUT PRESSURE
SCFM @ 90 PSI (620.5 kPa)
VOLTAGE
MINUMUM BRANCH CIRCUIT
REQUIREMENT
PUMP OIL CAPACITY
FUSE TYPE
REGULATED PRESSURE RATING
(APPROXIMATE)
QUICK CONNECT (E) TYPE
DUTY CYCLE
READ This OWnER's MAnUAl AnD sAFETY RUlEs
BEFORE OPERATing YOUR UniT. Compare the
illustrations with your unit to familiarize yourself with the
location of various controls and adjustments. Save this
manual for future reference.

On/Off Switch

Place this switch
 1 
in the ON position to provide automatic
power to the pressure switch and OFF to remove power at
the end of each use.
Pressure Switch
The pressure switch
9
automatically starts the motor when
the air tank pressure drops below the factory set "cut-in"
pressure. It stops the motor when the air tank pressure
reaches the factory set "cut-out" pressure.
Pressure Release Valve
The pressure release valve located on the side of the
pressure switch, is designed to automatically release
compressed air from the compressor head and the outlet
tube when the air compressor reaches cut-out pressure
or is shut off. The pressure release valve allows the motor
to restart freely. When the motor stops running, air will be
heard escaping from this valve for a few seconds. No air
should be heard leaking when the motor is running or after
the unit reaches cut-out pressure.
Safety Valve
If the pressure switch does not shut off the air compressor at
its "cut-out" pressure setting, the safety valve
against high pressure by "popping out" at its factory set
pressure (slightly higher than the pressure switch "cut-out"
setting).
D55166
59.5 lbs. (27 kg)
23.23" (590 mm)
10.04" (255 mm)
22.44" (569.9 mm)
6 Gallon (22.7 liters)
105 PSI (723.9 kPa)
135 PSI (930.7 kPa)
3.8
Check Valve
Single 120 V
When the air compressor is operating, the check valve
15 Amp
"open", allowing compressed air to enter the air tank. When
the air compressor reaches "cut-out" pressure, the check
10.6 oz. (313.5 ml)
valve "closes", allowing air pressure to remain inside the air
tank.
TIME DELAY
7-135 PSI
Tank Pressure Gauge
The tank pressure gauge
pressure in the tank.
1/4" (6.4 mm) INDUSTRIAL
Regulated Pressure Gauge
5 min ON, 5 min OFF
The regulated pressure gauge
available at the outlet side of the regulator. This pressure is
controlled by the regulator.
Regulator
The regulator
outlet pressure gauge. Turn regulator knob clockwise
to increase pressure and counterclockwise to decrease
pressure.

Drain Valve

The drain valve
is used to drain condensation at the end of each use. See
Draining Air Tank under Maintenance.
FIG. B
 2 
indicates the reserve air
indicates the air pressure
 3 
controls the air pressure shown on the
 4 
FIG. C
2
6
 8 
is located at the base of the air tank and
English
will protect
 7 
7
is
6
1
4
3
5
5

Publicidad

Tabla de contenido
loading

Tabla de contenido