5.1 List of device functions and components
(1) - Device socket for handpiece cable
(2) - Indicator light for foot pedal
(3) - Knob (potentiometer), setting parameters 1 -10
(4) - ON/OFF switch
(5) - Holder for entire handpiece
(Insert the edge of the handle (9) beneath the hook!)
(6) - Holding burl for attachable modelling blade (9)
(7) - Device socket for power supply cable plug
(8) - Device socket for foot pedal
(9) - Modelling blade incl. handle for holder on (5)
or storage block (12)
(10) - Hot needle (heat supply)
(11) -
Handpiece
(12) - Storage block for handpiece
The power supply cable plug is inserted into the control device bwm 3 device socket (7). The modelling blade
(9) is attached as far as the stop via the hot needle (10) and on the handpiece (11). The completed handpiece
is then pushed as far as the end position on the holder on the side of the device using the handle under the
retaining hook. Insert the handpiece cable into the device socket (1) intended for this purpose in the front
region. Switch the main switch (4) of the device to the on = I position; the indicator light on the main switch
illuminates green. Set the desired temperature on the knob (3). The temperature varies depending on the
setting parameter (steps 1-10), size and shape of the blade used.
5.2 Changing the modelling blade
Modelling blade incl. handle (9)
bredent GmbH & Co. KG · Weissenhorner Str. 2 · 89250 Senden · Germany · T: +49 7309 872-22
F: +49 7309 872-24 · www.bredent.com · @: info@bredent.com
(12)
Hot needle (10)
Handpiece (11)
13