Foot Pedal For Carrying Out Rapid Heating; Cleaning And Maintenance; Cleaning; Maintenance - bredent bwm 3 Manual De Funcionamiento Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
The modelling blade can be changed when it is hot. In order to do this, remove the hot modelling blade from
the hot needle (10) and handpiece (11) using the coloured handle (9).
Caution: Do not touch the hot needle or modelling blade - risk of burning!
Place the modelling blade (9) on one of the free holding burls (6) and move the desired modelling blade to the
end position on the handpiece (11). Wax resorption can be commenced again after approx. 10 seconds.

5.3 Foot pedal for carrying out rapid heating

The rapid heating function is useful if a higher temperature is required in the short-term or if a modelling
blade has been changed and needs to be brought to the right operating temperature quickly. Insert the foot
pedal cable into the socket (8) on the rear of the device. If a higher temperature is required than that which
has been set, the new heat output can be achieved by pressing the foot pedal. The temperature then returns
to the value set. The indicator light (2) illuminates when pressing the foot pedal. Wax resorption can be
commenced after approx. 10 seconds.

6. Cleaning and maintenance

6.1 Cleaning

Only clean the outside of the device using a lightly dampened cloth with the mains plug unplugged. Wipe
away wax residues using a cotton cloth. Do not use any cleaning products containing solvents!

6.2 Maintenance

The device is maintenance free for the customer.

7. Troubleshooting

Fault
Device does
not start/work!
no temperature control
possible

8. Declarations of conformity

bredent GmbH & Co.KG, Weissenhorner Str. 2, 89250 Senden, Germany, hereby declares that the control
device bwm 3 (electric wax knife) has been developed in accordance with the relevant provisions, European
directives and harmonised standards in view of the design and construction of the product in the form
brought to the market by us. The declaration of conformity can be requested if required.
14
Cause
network data and/or
connections,
parameters are not correct
network cable defective –
cable breakage, defective
contact
potentiometer, error in
temperature control
bredent GmbH & Co. KG · Weissenhorner Str. 2 · 89250 Senden · Germany · T: +49 7309 872-22
F: +49 7309 872-24 · www.bredent.com · @: info@bredent.com
Troubleshooting
- Compare data with type-plate
- Insert mains plug
- Set start button to ‚l'
renew network cable
Contact bredent service or
authorised dealer
and have the control panel replaced
- send in device