Service (Continued):
FAN BLADES:
Blades should be cleaned at least once per
heating season, depending on conditions.
Remove all accumulated dust and dirt with a
damp cloth, taking care not to bend any of the
fan blades. Be sure the blades are dry before
re-starting the heater. For fan assembly removal
see Figure 14.
Figure 14
FUEL FILTER:
The fuel filter should be cleaned at least twice
per heating season. Clean the filter by rinsing
it in clean 1-K Kerosene. Contaminated fuel
could make cleaning the fuel filter necessary
immediately.
NOTE: To remove the filter from models 45
/ 70T / 75T-KFA turn filter 90º clockwise. To
remove the filter from models 125T / 175T /
215T-KFA turn filter 90º counter-clockwise.
Figure 15
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
®
Maintenance
Set Screw
Motor Shaft
Fan Blade
Fuel Filter
Fuel Line
Side Cover
SPARK PLUG:
Clean and re-gap every 600 hours of operation, or
replace as needed. After removing the spark plug,
clean the terminals with a wire brush. Re-gap the
terminals to 0.140" (3.5mm) See Figure 16.
Burner Head
Figure 16
PHOTOCELL:
The photocell should be cleaned using a cotton
swab dipped in alcohol or water at least once
per heating season, or more depending on
conditions. See Figure 17.
Photocell Wire
Figure 17
Kerosene Forced Air Heater User's Manual
10
Spark Plug
Gap
Ignitor Wire
Photocell
Photocell lens
X
X