Fueling The Heater:
Kerosene (1-K)
For optimal performance of this heater, it is
strongly suggested that 1-K kerosene be used.
1-K kerosene has been refined to virtually
eliminate contaminants, such as sulfur, which can
cause a rotten egg odor during the operation of
the heater. Using diesel fuel can cause excess
soot production. Do not use Bio-Diesel as this
fuel will damage your heater's seals and filter.
- CSA certified for use with 1-K kerosene,
no. 1 & no. 2 diesel, JP8/Jet A Fuel,
no. 1 and no. 2 fuel oil.
DO NOT use any fuel that is not approved above.
NEVER REFUEL THIS HEATER
DANGER
WHILE IT IS HOT OR
OPERATING. FIRE OR EXPLOSION COULD
RESULT.
NEVER FILL THE FUEL TANK
CAUTION
INDOORS. ALWAYS FILL
THE TANK OUTDOORS. BE SURE THAT
THE HEATER IS ON LEVEL GROUND WHEN
FUELING, AND NEVER OVERFILL THE TANK.
DO NOT USE GASOLINE OR
WARNING
CRANKCASE DRAININGS.
- NEVER use fuel such as, benzene, alcohol, white
glass, camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR
EXPLOSION.
- NEVER store kerosene in the living space.
Kerosene should be stored in a well ventilated area
outside the living area.
- NEVER store kerosene in direct sunlight or near a
source of heat.
- NEVER use kerosene that has been stored from
one season to the next. Kerosene deteriorates
over time. OLD KEROSENE WILL NOT BURN
PROPERLY IN THIS HEATER.
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
®
Operation
NOTE: Kerosene should only be stored in a blue
container that is clearly marked "Kerosene."
Never store kerosene in a red container. Red is
associated with gasoline.
Ventilation:
- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well
ventilated areas.
- Refer to Safety Information on pages 1-2 for
information about Carbon Monoxide Poisoning.
CARBON MONOXIDE POISONING
DANGER
MAY LEAD TO DEATH!
- ALWAYS provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm)
for each 100,00 Btu / Hr. of heater output. Provide
a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
45-KFA
70T-KFA
75T-KFA
1.4 ft.²
2.1 ft.²
1250 cm²
1950 cm²
2090 cm²
Optional Electrical Outlet:
- Never plug an appliance with more than a 5 amp
rating into this outlet (See Figure 8).
- Always keep outlet covered when not in use.
Optional Electrical Outlet
Figure 8
Kerosene Forced Air Heater User's Manual
7
125T-KFA
175T-KFA 215T-KFA
2.3 ft.²
3.8 ft.²
5.3 ft.²
3480 cm²
3760 cm²
6.5 ft.²
5990 cm²