Function
DC voltage
(V =)
AC voltage
(V ) 50/60 Hz
AC current
(A )
Resistance
()

8. Operating Instructions

Set the rotary switch to the selected range prior measuring. In case of changing
the function or range please remove the test leads (or the clamp) from any source
of voltage.
Range
Resolution
200 mV
0,1 mV
2V
1 mV
20 V
0,01 V
200 V
0,1 V
400 V
1 V
200 mV
0,1 mV
2V
1 mV
20 V
0,01 V
200 V
0,1 V
400 V
1 V
2 A
10 mA
20 A
0,1 A
200 A
1 A
400 A
200 
100 m
1 
2 k
10 
20 k
100 
200 k
2 M
1 k
20 M
10 k
Accuracy of the value displayed
in %
(0,8% + 2 Digits)
(1,5% + 2 Digits)
(2,0% + 2 Digits)
(1,5% + 35 Digits)
(1,8% + 8 Digits)
(2,5% + 8 Digits)
(2,5% + 10 Digits)
(2,5% + 4 Digits)
(3,0% + 4 Digits)
(1.0% + 4 Digits)
(1.5% + 2 Digits)
(2,5% + 3 Digits)
(3,5% + 5 Digits)
EN 9