Multiple Plp-Rem-350 Installation - Duratech PLP-REM-350 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Multiple PLP-REM-350 installation

1) Connect the DMX panel to the "DMX IN" port of the first PLP-REM-350
2) Connect the PLP-REM-350's with each other (open loop):
DMX OUT --> DMX IN (polarized terminals + -)
3) Set the DMX address for each PLP-REM-350 via the address dial.
- Option 1: All PLP-REM-350's can be set to the same address:
This implies that all lamps will receive the same DMX data,
And will all operate identically
- Option 2: PLP-REM-350's can be set to different addresses:
Each PLP-REM-350 will have it's own group of connected lamps
that will operate identically.
However, since each PLP-REM-350 has it's own unique address,
the different lamp groups can be controlled separately
Address dial
PLP-REM-350
230VAC
DMX PANEL
PLP-REM-350
230VAC
Address dial
Address dial
PLP-REM-350
230VAC
13

Publicidad

Tabla de contenido
loading

Tabla de contenido