"Limit and enable password legitimation" instruction (ENDIS_PW)
To disable the protection with an F-CPU, you must uninstall the CPU and reinstall it. A repair installation is not sufficient to
reset the configured access protection via the ENDIS block.
Monitor cable on DisplayPort X70/X71
If the monitor cable is connected to the DisplayPort X70/X71 while the SIMATIC IPC is switched on, it can happen that a
newly inserted display is not correctly detected and that the display contents are not shown correctly. In rare cases this can
lead to the "Defect" of the SIMATIC CPU1507S (F) Software Controller.
Do not plug or unplug the display cable of the SIMATIC IPC while the CPU1507S Software Controller is in operation. If the
behavior occurs, you need to restart the SIMATIC IPC with connected display.
We recommend leaving the display connected to the IPC or operating the IPC without connected display at all times.
Reference information for use with SIMATIC IPC
Windows Knowledge Base
The BIOs versions named in the reference information for the SIMATIC IPCs requires that the Windows KBs for repairing
the Meltdown and Spectre security gaps have been installed.
Ensure that the following KBs are installed:
● Windows 7:
–
KB 4056897
–
KB 4074598
–
KB 4100480 (valid for 64-bit version only)
● Windows 10:
–
KB 4056890
Note
Special feature for new SIMATIC IPCs
On the latest SIMATIC IPCS the above-mentioned security updates are already an integral part of the basic system. Before
you install the software controller, check to see whether these KBs have already been installed and, if not, install them
manually.