ENG
Now keep the SET-key (fig. 1.6)
pushed in for a long time until the
temperature indication in the display
screen starts to blink.
In accordance with your wishes,
increase the Night temperature with
the
-key (fig. 1.9) or lower it with
the -key (fig. 2.0).
Note! The lowest temperature that
can be set is 5 ºC. If you don't want
the hearth to switch on at night, keep
pressing the -key (fig. 2.0) until the
sign - - appears in the display screen.
Save the settings by pressing the
OFF- key (fig. 1.8) or wait for ten
seconds.
2.9.2
Programming the timer setting
Move the SET-key (fig. 1.6) step by
step to TIMER.
Now keep the SET-key (fig. 1.6)
pushed in for a long time until the
time indication in the display screen
starts to blink and P1 is visible.
Set the starting time P1 (getting up)
of the day temperature with the
key (fig. 1.9) for the hours and with
the -key (fig. 2.0) for the minutes.
Now press the SET-key (fig. 1.6)
again, now P1 (departure) will
appear in the display screen and the
time indication will start to blink and
now set the starting time.
For setting the 2
SET–key (fig. 1.6) and P2
(homecoming) will appear in the
display screen, the time indication
will start to blink and now set the
starting time.
nd
If a 2
period setting is not
o
desired, save the settings by
pressing the OFF- key (fig.
1.8) or wait for ten seconds.
Press the SET–key (fig. 1.6) again,
now P2 (night) appears in the
display screen, the time indication
will start to blink and now set the
starting time.
Save the settings by pressing the OFF-
key (fig. 1.8) or wait for ten seconds.
2.10
Checkpoints in case of
malfunction
If the remote control unit of the hearth does
not function properly, check the following
points first:
1. Is knob A set to position ON.
(fig. 1.3)?
13 <
<
<
<
-
nd
period, press the
2. Check the battery- and/or mains
voltage of the adapter. (paragraph.
2.4.4)
3. Check whether the receiver responds
to the remote control unit.
If necessary, reset the receiver or set
a new transmitter code.
Before resetting, briefly press the
reset button on the receiver
(fig. 2.3.1), for setting the
transmitter code: see paragraph
2.5.2.
4. If unintentional the start-process
started when the fire is in operation,
the step-burner will not operate for
45 sec.
If the remote control unit or the hearth itself
does not function properly after all these
checks, we refer you to your gas fitter.
2.11
Manual ignition (by the gas fitter)
This action is intended for service purposes
only.
Take the following steps:
1. Remove the ignition cable of the
receiver (fig. 1.2-G) and place this on
the gas block. (fig.1.3-D)
2. Twist the knob B to the right with
the arrow to the OFF position.
(fig.1.3)
3. Twist the dial A to the right with
the arrow in the MAN position
(fig.1.3). Now the pilot light valve C
and the piezo-ignition E are
accessible.
4.
Use a screwdriver to keep the pilot
light valve C pressed in,
simultaneously press the piezo-
ignition E (fig.1.3 ) briefly a few
times, the pilot light will ignite now.
5. If the pilot light is burning, wait for
approx. 20 seconds before releasing
the pilot light valve.
6. Now twist the dial A to the left
with the arrow to the ON position.
(fig.1.3 )
7. Now the flame height can be adjusted
by twisting the knob B to the left
past the ON position.(this causes a
rattling sound!) (fig.1.3 )
8. The step-burner can not be switched
manual