5 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
M1
2
3
4
M2
5
6
7
8
9
M3
10
11
12
13
14
15
16
M4
17
18
19
Signal
PHASE
115 Vac power supply
NEUTR
115 Vac power supply
Flashing light output 115Vac 40W.
LAMP
Slow flashing in opening, turned off in pause, fast flashing in closing.
Motor connection (opening)
OPEN
COM
Motor common
CLOSE
Motor connection (closing)
PEDESTRIAN (N.A.) input
The pedestrian manoeuvre is made after the closing of this contact or by
the relay 2 of the plug-in two-channels receivers.
Operation in reply to a PEDESTRIAN command:
Ÿ Gate closed
PED
Ÿ During the opening
Ÿ Gate open
enabled, otherwise CLOSES.
Ÿ During the closing
START
START (N.A.) input. See DIP SW1_1 and SW1_2, Chap.8
PHOTOCELL (N.C.) input, see operation DIP SW1_5, Chap.8.
PHOTO
If not used,make a jumper with terminal n°13
SAFETY DEVICES (8K2) input.
After the intervention of the safety device, the control unit stops the motion, inverts it for
SAFETY
1 second and waits for a command.
If not used, make a bridge with terminal n°13, using a 8K2 Ω resistance
SAFETY DEVICES / STOP (8K2) input, selectable by DIP SW1_10.
SAFETY
See description DIP SW1_10.
/
If not used, make a bridge with terminal n°13, using a 8K2 Ω resistance
STOP
COM
COMMON INPUTS-OUTPUTS
COM
COMMON INPUTS-OUTPUTS, COMMON MOTOR RPM SENSOR (BLUE CABLE).
24Vac
Power supply 24Vac external accessories (photocells, radio, etc) 8W Max
TEST
Power supply 24Vac for external safety devices tested, 8W Max .
/
Power supply 24Vac for external devices submitted to ENERGY SAVING.
ENERGY
See operation DIP SW1_4, Chap.8.
SAVING
WARNING LIGHT 24Vac 3W max. input
SPIA
Slow flashing in opening, turned on fixed in pause, fast flashing in closing.
+12Vdc
Inductive sensor power supply (brown cable)
IMP
Inductive sensor input (black cable)
Description
→
OPENS for 10 seconds (not adjustable).
→
IRRELEVANT
→
IRRELEVANT if the automatic reclosing is
→
OPENS completely.
SC230