INSTALLATION INSTRUCTIONS
L7XR, L7XFR, L7XPR,
L5R, L3R, LV3R
Make certain that all power is disconnected prior to installing the fixture.
Make all necessary wiring corrections, observing proper voltage and polarity. Ensure that wires are not being pinched.
INSTALLATION
This unit can be installed in a TYPE IC or TYPE NON-IC installation:
TYPE IC: Where the rough-in section is in direct contact with insulation. Match trims
listed on IC portion of the fixture label for IC installations. Remove the peel off label on
top of the housing stating not to install insulation within 3 inches (76mm) of any side of
the fixture (See Figure 1). L3R and L7XR only.
TYPE NON-IC: Where no insulation is placed over the top or within 3 inches (76mm) of
the sides of the rough-in section. Match trims listed on the NON-IC portion of the fixture
label for NON-IC installations.
This product is Air Tight and conforms to maximum air leak rate of less than 2.0 CFM as tested per ASTM E-283 method. Product
must be sealed to ceiling surface to eliminate all air paths into space above. The gap between the drywall edge and the edge of the
recessed fixture must be sealed by the installer using drywall compound (not provided) or silicone caulking (not provided) rated for a
minimum of 90 degree C to seal the gap.
MOUNTING INSTRUCTIONS
1.
Using template (inside housing) to outline circle on ceiling.
2.
Use keyhole saw to cut out circle on ceiling.
3.
NOTE: when deciding on fixture placement and preparing to cut hole, take into
account joist placement and electrical wiring requirements. Your ceiling material must
be non-combustible and strong enough to support fixture.
4.
Make sure clips are properly seated in can.
5.
Tilt fixture up through hole.
6.
Hold fixture up against ceiling and push retaining clips against can (See Figure 2).
WIRING
Make certain all power is disconnected prior to installing the fixture. Open the snap-on junction
box captive door and remove the appropriate pry-out with screwdriver. Built in Romex clamps
are accessible through the Romex pry-outs (See Figure 3). Bring supply wires into box by
shielded cable or Romex cable.
Make all connections inside the junction box. Connect 120V hot wire to the black wire.
Connect the neutral wire to the white wire. Connect the ground wire to the bare copper
wire. This fixture should be wired in accordance with the NEC and applicable local codes
and ordinances.
TRIM INSTALLATION
SEE TRIM INSTRUCTION SHEET FOR DETAILS
LAMP INSTALLATION
Prior to installing lamp (not included) in the fixture, check to make sure that all power is disconnected. Ensure that the lamp source and
wattage corresponds with the fixture label and the trim label. To properly seat the lamp into the fixture, screw the lamp securely into the
socket. Back the lamp out one to two turns, and then screw the lamp back into the socket, making sure that it is secure.
Follow lamp manufacturer's instructions regarding lamp operation and re-lamping. Operating a fixture with a lamp that turns on and off, an
extinguished lamp, or no lamp at all may cause damage to the components and will void all warranties.
Lithonia Lighting
Downlighting
One Lithonia Way / Conyers, GA 30012
800-315-4935 / www.lithonia.com
Figure 1
Figure 2
Figure 3
Part Number: CJ520107 Rev. B
©2008 Acuity Brands Lighting, Inc., 10/08