Cleaning Instructions - LB White Guardian AD060 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cleaning Instructions

WARNING
Fire, Burn, and Explosion Hazard
■ This heater contains electrical and mechanical
components in the gas management, safety
and airfl ow systems.
■ Such components may become inoperative or
fail due to dust, dirt, wear, aging, or the cor-
rosive atmosphere of an animal confi nement
building.
■ Periodic cleaning and inspection as well as
proper maintenance are essential to avoid
serious injury or property damage.
1. Before cleaning, close fuel supply valve to
heater and disconnect electrical supply.
2. The heater should have dirt or dust removed
periodically:
a. After each fl ock or between building re-popula-
tion, give the heater a general cleaning using
compressed air or a soft brush on its interior
and exterior. At this time, dust off the motor
case to prevent the motor from over-heating
and shutting the heater down.
b. At least once a year, give the heater a
thorough cleaning. At this time, remove the fan
and motor assembly and brush or blow off the
fan wheel, giving attention to the individual fan
blades. Additionally, make sure the burner air
inlet venturi ports and the throat of the casting
are free of dust accumulation and the area
between the heat chamber top and inside case
is also free of dust.
c. When washing with water, observe and obey
the Warning within these Cleaning Instruc-
tions. This same Warning is also supplied on
the heater.
Guardian with Smart Sense™
WARNING
This heater may be washed only on the external
case assembly provided:
A. The heater is disconnected from the electrical
supply.
B. All access panels are securely closed.
C. Water spray nozzle shall not discharge within
6 feet of the heater.
D. The water pressure does not exceed 45 PSIG
for 10 seconds on each side of heater.
E. The heater is not reconnected to electrical
supply for a minimum of 1 hour or until the
heater is thoroughly dry.
Improper cleaning of the heater can cause
severe personal injury or property damage due to
water and/or cleaning solution:
1. In electrical components, connections and
wires causing electrical shock or component
failure.
2. On gas control components causing corrosion
which can result in gas leaks and fi re or explo-
sion from the leak.
Clean internal components of the heater with a
soft, dry brush or cloth, or compressed air.
Owner's Manual • Guardian
17

Publicidad

Tabla de contenido
loading

Productos relacionados para LB White Guardian AD060

Tabla de contenido