Need help? 1-866-439-9800, 8 a.m - 8 p.m., EST, Monday - Sunday.
Operating Instructions
Checking for Leaks
W WARNING: Before using this outdoor
fire pit, make sure you have read,
understand and are following
all information provided in the
"Important Safeguards" section
on page 2. Failure to follow those
instructions can cause death, serious
injury or property damage.
W WARNING: The burner must be
replaced prior to the appliance being
put into operation if it is evident
that the burner is damaged. The
replacement burner shall be that
specified by the manufacturer.
Burner Connections
1 .
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank .
2 .
Visually check the connection between the
burner/venturi tube and orifice .
3 .
Make sure the burner/venturi tube fits over the
orifice .
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4 .
Refer to diagram for proper installation (Figures
1 and 2) .
5 .
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1-866-439-9800 for assistance .
Tank/Gas Line Connection
1 .
Make 2-3 oz . of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water .
2 .
Make sure control knobs are in the " OFF"
position (Figure 3) .
3 .
Connect LP gas tank per "Installing LP Gas
Tank" section .
4 .
Turn LP gas tank valve to "OPEN ."
5 .
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 2) .
a . If any bubbles appear, turn LP gas tank valve
to "CLOSED," reconnect and re-test .
b . If you continue to see bubbles after
several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per
"Disconnecting LP Gas Tank" section . Contact
1-866-439-9800 for assistance .
c . If no bubbles appear after one minute, turn
LP gas tank valve to "CLOSED," wipe away
solution and proceed .
Lighting
W DANGER: Failure to follow these
lighting instructions may result in
serious bodily injury or death, or in a fire or an explosion causing
damage to property.
W WARNING: NEVER light the burner with the cover on the outdoor
fire pit.
W CAUTION: Keep outdoor gas appliance area clear and free from
combustible materials, gasoline and other flammable vapors and
liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1 .
Make sure all labels, packaging and protective films have been removed from the outdoor
fire pit .
2 .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
3 .
Control knob must be in the " OFF" position (Figure 3) .
4 .
Clear small area of fire glass away from the igniter cover (Figure 4) .
5 .
Connect LP gas tank per "Installing LP Gas Tank" section .
Do not return to place of purchase
Figure 1
Burner Venturi
Pipe
LP Gas
Connection
X
X
X
LP Gas Valve
with Orifice
Burner Supply
Tube
Figure 2
X
X
X
X
X
Figure 3
OFF / ARRÊT
Figure 4
Figure 5
15.75 in - 23.6 in
40 - 60 cm
Operating Instructions (continued)
1 .
Turn LP gas tank valve to "OPEN ."
2 .
Push and turn control knob to (HIGH) . Continue to hold the control knob in to light .
3 .
After the fire pit lights, continue to hold the control knob in for 20 seconds to heat the
thermocouple, a safety device that stops the gas flow when a firepit is not lit . Holding the
knob in for 20 seconds warms it up so the gas flow will continue .
4 .
After 20 seconds, release and turn control knob counterclockwise to adjust flame to
desired height .
5 .
After three attempts, if ignition does not occur, turn the burner control knob to " OFF ."
6 .
Wait 5 minutes, fan with a newspaper or magazine, and repeat lighting procedure .
7 .
If igniter does not light burner:
a .
Wearing heat-resistant gloves, position a lit long match or lit long butane lighter near
the pilot housing .
b .
Push and turn control knob to (HIGH) .
c .
Remove match/lighter once burner is lit .
W CAUTION: After lighting - using a fire pit tool and heat-resistant
gloves, carefully move the fire glass/lava rock back to their proper
position, being careful to avoid the flame.
8 .
After lighting, observe the burner flame . Make sure all burner ports are lit and flame height
matches illustration (Figure 5) .
W CAUTION: If ignition does not occur in 5 seconds, turn control knob
to " OFF," wait 5 minutes, fan with a newspaper or magazine, and
repeat lighting procedure.
Turning Off
1 .
Turn LP gas tank valve to "CLOSED ."
2 .
Turn control knob to the " OFF" position .
Note: A "poof" sound is normal as the last of the LP gas is burned .
3 .
Disconnect LP gas tank per "Disconnecting LP Gas Tank" section .
Cleaning and Care
W CAUTION:
1. All cleaning and maintenance should be done when outdoor fire pit
is cool and with the fuel supply disconnected.
2. Do NOT clean any outdoor fire pit part in a self-cleaning oven. The
extreme heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports when cleaning the
valves or burners.
4. All components on this outdoor fire pit can become hot.
5. Do NOT clean this outdoor fire pit until all components are cool.
Notices
1.
This outdoor fire pit should be thoroughly cleaned and inspected on a regular basis.
2.
Abrasive cleaners will damage this product.
3.
NEVER use oven cleaner to clean any part of this outdoor fire pit.
Before Each Use:
1 .
Keep the outdoor fire pit area clear and free from any combustible materials, gasoline, and
other flammable vapors and liquids .
2 .
Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air .
3 .
Keep the ventilation opening(s) of the LP gas tank area free and clear from debris .
4 .
Visually check the burner flames to make sure your outdoor fire pit is working properly
(Figure 5) .
5 .
See below for proper cleaning instructions .
6 .
Check all gas connections for leaks .
7 .
Check components for any signs of damage or rust .
8 .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner/venturi tube can lead to a fire .
9 .
If damage to any component is detected, do NOT operate until repairs are completed .
Cleaning Surfaces
1 .
Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water .
2 .
For stubborn stains, use a citrus-based cleaner and a nylon scrubbing brush .
3 .
Rinse clean with water .
4 .
Allow to air dry .
Note: While cleaning your unit, be sure to keep the area around the burner and pilot assembly
dry at all times .
W CAUTION: Do NOT submerge the control valve assembly. If the gas
control is submerged in water, do NOT use it. It must be replaced.
9