4.1 Pit Installation

i WARNING
Do not install lift in a pit unless pit has a bevel toe guard or
other approved toe protection. A shear point may exist which
can cause severe foot injury.
Lift platforms traveling below floor levels may create a toe hazard as load
passes top edge of pit. This may require guarding in accordance with
Federal Regulations. Guarding must be installed prior to operating lift.
1. Check pit dimensions. Pit must be 2" longer and 2" wider than lift platform to allow a 1" gap
between platform and pit. Pit depth should allow ½" for shims or grout.
2. Conduit (F) diameter must be a minimum of 2".
A – Lift Platform
B – 1" Gap Between Deck And Pit Wall
C – Pit Access Hatch, Optional, Installed By Customer
D – Pit Curb Angle, Suggested Min. L2" x 2" x ¼", Cust. Inst.

4. INSTALLATION

15
E – Lift Anchor Points (4)
F – 2" Min. Conduit, Cust. Inst.
G – Suitable Pit Drain, Cust Inst.
H – ½" Grout Under Base