Problem
Fan/Light does not
operate when button is
turned ON
Fan does not operate
when fan + or – buttons
or MEMORY/OFF
button is pressed
Loud or abnormal
airflow noise
Fan fails to circulate
air or moves air slower
than normal and/or
fan is making loud or
abnormal airflow noise
The hood controls are
not operating correctly
Early bulb failure
Hood does not appear
to operate when the
MEMORY/OFF button
is pressed. All collars
around the push
buttons are illuminated.
49-2000833 Rev. 0
Possible Cause
A house fuse may be blown or a circuit
breaker tripped.
The blower connector is loose or not
plugged into its mating connector
Wrong duct size used in installation.
Obstructions in duct work.
Damper blade on wall or roof cap may
not be open.
Metal grease filter and charcoal filter (if
present) may be dirty.
Insufficient makeup (replacement) air
Control logic confused
Replacing bulbs with bare hands
The memory feature of this hood has not
been set. This is normal.
What To Do
Replace fuse or reset circuit breaker.
Disconnect power to the unit. Remove the filters and
look up at the blower. If the blowe connector plug is
loose or you see the connector dangling, the installer
failed to plug it in securely. See the installation
instructions for the plug location and how to plug in the
connector.
This hood requires 8" ducting to perform optimally.
Using smaller duct pipe will cause reduced venting.
Minimize the duct run length and number of transitions
and elbows. GE Appliances service technicians cannot
correct this issue if installed improperly.
Make sure nothing is blocking the vent. Make sure
your wall or roof cap has a blade or door.
Make sure damper swings freely. Damper blades may
flip over and will not fully open when this happens.
Adjust to original position.
Clean the metal grease filter and replace charcoal filter
(if present). See Care and Cleaning of the Vent Hood.
Sufficient makeup (replacement) air is required for
exhausting appliances to operate to rating. Check with
local building codes, which may require or strongly
advise the use of makeup air. Visit GEAppliances.com
for available makeup air solutions.
Disconnect power to the hood by resetting the circuit
breaker. Wait 30 seconds to allow controls to reset
Replace bulbs while wearing gloves to keep skin oils
off bulb. Bulb wattage is too high. Replace with correct
wattage.
Follow procedures for setting the MEMORY/OFF
button. Adjust the Fan and Light settings to your
preference.