NOTE: If you need to install ducts, note that the total
duct length of 3
1 4
duct should not exceed 140 equivalent feet.
Outside ventilation requires a HOOD EXHAUST DUCT.
Read the following carefully.
NOTE: It is important that venting be installed using
the most direct route and with as few elbows as possible.
This ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
Exhaust connection:
The hood exhaust has been designed to mate with
a standard 3
1 4
If a round duct is required, a rectangular-to-round
transition adaptor must be used. Do not use less than
a 6 diameter duct.
DUCT PIECES
Rectangular-to-Round
Transition Adaptor*
Wall Cap
90° Elbow
45° Elbow
90° Elbow
45° Elbow
Roof Cap
3
1 4
* IMPORTANT: If a rectangular-to-round transition
adaptor is used, the bottom corners of the
damper will have to be cut to fit, using the tin
snips, in order to allow free movement of the
damper.
4
Installation Instructions
EQUIVALENT
LENGTH
5 Ft.
40 Ft.
10 Ft.
5 Ft.
25 Ft.
5 Ft.
24 Ft.
Maximum duct length:
For satisfactory air movement, the total duct length of
3
1 4
not exceed 140 equivalent feet.
Elbows, transitions, wall and roof caps,
etc.,
present additional resistance to airflow and are
equivalent to a section of straight duct which is longer
than their actual physical size. When calculating the total
duct length, add the equivalent lengths of all transitions
and adaptors plus the length of all straight duct sections.
The chart below shows you how to calculate total
equivalent ductwork length using the approximate feet of
equivalent length of some typical ducts.
NUMBER
x
USED
x
(
)
x
(
)
x
(
)
x
(
)
x
(
)
x
(
)
x
(
)
Total Ductwork
Equivalent lengths of duct pieces are based on actual tests
and reflect requirements for good venting performance with
any vent hood.
should
=
LENGTH
=
Ft.
=
Ft.
=
Ft.
=
Ft.
=
Ft.
=
Ft.
=
Ft.
=
Ft.
31-7000091 Rev. 2