Safety Instructions; Installation Requirements - FOTILE SD2F-P1X Manual De Operación

Fregadero lavavajillas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

I. Safety Instructions
To avoid injury and property damage to users and other persons, please read and observe all safety
instructions and warnings.
1. The personnel installing this product must have basic mechanical, electrical and plumbing skills.
This product must be installed by certified professional plumbers.
2. It is the responsibility of the installer for correct installation, any product fault caused by improper
installation will not be covered by the FOTILE warranty.
3. Disconnect the power before installing the product to prevent electric shock.
4. Do not wet the power cable, power plug, connectors or other electric parts, or it may cause electric
shock or other accidental damages.
5. Do not modify, stretch, knot the power cable or place heavy objects on it. Doing so may cause
damage to the power cable and result in electric shock, fire, etc.
6. Do not touch the power cable or electrical parts with wet hands, or it may cause electric shock.
7. The Sink Dishwasher must be connected to a grounded electrical outlet. If you don't have a
grounded electrical outlet, please have a certified electrician install one. Failure to do so can
result in electrical shock and injury.
8. If the power cable is damaged, it must be replaced by Fotile Service Technicians to avoid danger.
9. During installation, please pay attention to the edges and corners of the sink to avoid scratches.
10. Only cold water can be supplied to the water inlet of the Fotile sink dishwasher. Supplying hot
water will affect the produce cleaning function for fruits and vegetables. The FOTILE Sink Dish-
washer uses its' own heating element to heat water for dishwashing.
11. Do not allow children to play with the plastic film or other packaging components which may
cause asphyxiation and possible death.
12. The countertop which the product is installed into must have sufficient strength to support 220
Ibs (100Kg). Please follow all mounting directions to be firmly installed into the countertop
correctly.
13. The countertop which this product is installed into, must be made from temperature and humidity
resistant materials.
14. During product installation, the functional sink must maintain a distance of 11 13/16 "(300mm) or
more from the gas meter and the gas pipeline. The junction box must be a distance of 5 15/16"
(150mm) or more from the gas meter and gas pipeline.
15. Please adhere to all local laws and regulations for the connection of the drain hose.
16. Please save this Installation Manual for future reference.
-2-
II. Installation Requirements
To avoid injury and property damage to users and other persons, please read and observe all safety
instructions and warnings.
1. Objects obstructing the functional sink and drain line such as a gas line or gas meter should not
be installed in the cupboard;
Hose and equipment
Exposed insulated wire or cable
Exposed wire with voltage less than 1,000V
Electrical
Switchboard or distribution box, electricity meter
equipment
Electrical socket, power switch
2. The water supply and power socket should be arranged in the cupboard (or the adjacent
cupboard).
3. The 240V/60Hz power supply shall be provided. A wire with a diameter of more than 16AWG (1.5
mm2) should be used and reliably grounded.
4. The pressure of the installation waterway should meet the requirements of 20.3 psi-145.04 psi.
5. Height requirements for drain hose: The height from the top of the installed countertop to the drain
hose should be greater than or equal to 21 11/16 "(550mm).
Mesa
Ground
6. Opening size of the countertop and size requirements in the cupboard
Opening size of the countertopt
Length
Length
Length
Length
38"
18 1/8"
7/16"
≥38 1/4"
Net Distance from Gas Hose
Parallel Lying
Cross Lying
9 7/8"(250mm)
3 15/16"(100mm)
39 3/8"(1,000mm)
39 3/8"(1,000mm)
11 13/16"(300mm)
Not allowed
5 15/16"(150mm)
Not allowed
Mesa
Ground
Inner wall size of cupboard
Length
Length
≥20 1/8"
≥35 7/16"