1.1.2 Description of the menus
ICON
FUNCTION
Power
Fan
Temperature
Fuel
Timer
ICON
FUNCTION
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Setup
[9]
[10]
[12]
[13]
[14]
[30]
[39]
[40]
Submenus [30] and [40] in the Setup menu are password-protected and reserved for service centre personnel.
16
Stove output setting
This parameter is not enabled on water heating models
probe*
Displays the
temperature reading and is used to set the desired temperature.
water
*config.1:
probe; config.2: room probe; config. 3-4: external/tank probe.
Not used
Enables or disables the timer. When enabled, the icon
flashing)
SUBMENU
[1]
Weekly timer
Assigns the programs (max 3) to the different days of the week
Programs
Program setting menu
Time / date
Time and date setting
Displays the number of hours remaining until recommended maintenance.
Hours remaining
When "Hi" is displayed, the remaining time exceeds 999 hours.
System
Displays the current software version
information
It allows to set the desired temperature for the water supply (only in
Water temperature
configuration 2).
Enables or disables Eco Mode, in which the stove automatically switches
Eco function
off and on based on room temperature (only in configuration 2).
Is the number of degrees centigrade below the switch-off temperature at
Restart delta
which the stove switches on again automatically (except in configuration
1).
Frost protection
Minimum temperature below which the stove switches on (except in
configuration 1).
temperature
Lock keypad
Disables the buttons on the keypad
[11]
Display brightness Sets display brightness
Display mode
Sets how the data is displayed
Buzzer volume
Sets the buzzer volume
Type of pellets
Three different types of pellet can be set
Installer menu
Sets/displays the stove configuration
System
Instantly calculated consumption parameters
information
Service menu
Menu reserved for the service centre
004773290 - 22/03/2021
DESCRIPTION
will be displayed steady (not
DESCRIPTION
VALUES
1..5
config.1: 65..80 °C
config.2: 10.. 48 °C
config.3-4: 45..75 °C
ON - OFF
VALUES
[d1] ... [d7]
[P1] ... [P6]
60 ... 80°C
OFF; Eco
0,5 ... 5,0°C
0 ... 40°C
OFF; 3 ... 20 °C
OFF; 3 ... 50 °C
OFF; Lo; Hi
OFF; 1 ... 5
OFF; 1 ... 4
OFF; 1 ... 5
1 ... 3
PWD: "54"
-