Mark Pointer On Bayonet Ring - WIKA NS 63 Manual Del Usuario

Ocultar thumbs Ver también para NS 63:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Adjustable pointers

3.2 Mark pointer on bayonet ring

Mark pointers indicate the defined limit value of the relevant process. The setting of this mark
pointer is made by moving it on the bayonet ring.
CAUTION!
EN
Damage to the instrument!
Errors with the handling of the clamping screw can damage the instrument:
- If the screwdriver slips off the screw head, the window could be damaged.
- If the clamping screw is fastened too tight, the bayonet ring can be deformed.
The setting of the mark pointer is carried out as follows:
Mark pointer on bayonet ring
Clamping screw
1. Carefully loosen the clamping screw on the mark pointer with a matching screwdriver.
2. Slide the mark pointer on the bayonet ring until the pointer indicates the desired scale
value.
3. Carefully screw the clamping screw on the mark pointer back down, hand tight.
6
Loosen/tighten the clamping screw with care.
Screwdriver for hexalobular socket T8
Additional information for pointers of dial gauges

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ns 100Ns 160

Tabla de contenido