10. Reconnect power to liftgate.
Remove nut from negative
(-) battery terminal (FIG. 9-1).
Connect negative (-) battery
cable to the negative (-)
battery terminal (FIG. 9-1).
Install and tighten nut.
11. Verify street side control works
correctly. Push switch to UP posi-
tion to raise platform (FIG. 9-2).
Then, push switch to DOWN po-
sition (FIG. 9-2) to lower platform
to the ground.
12. Peel and separate up decal and
down decal from decal sheet (Kit
item), then attach to control switch
as shown in FIG. 9-3.
© MAXON Lift Corp. 2018
LIFT CORPORATION Sht. 9 of 18 DSG#
M-16-08
NEGATIVE (-)
BATTERY CABLE
RECONNECTING POWER
VERIFYING DUAL CONTROL SWITCH
UP & DOWN
DECALS
ATTACHING DECALS
Rev. A Date: 07/02/18
NEGATIVE (-)
BATTERY TERMINAL
NUT
FIG. 9-1
FIG. 9-2
CONTROL
SWITCH
FIG. 9-3
UP
DN