BRS-LCi VW
6.4 Setting up the clamping position
1
Fig. 6
1 Move the torch with the gas nozzle (1) vertically to the tool axis (milling cutter axis) over the cleaning
station BRS-LCi (2) (P1).
2 Approach the clamping position (P2). Make sure that the cylindrical part of the gas nozzle (1) lies evenly
against the prism (3).
6.5 Setting up the compressed-air motor
1
2
3
Fig. 7
1 Loosen the compressed-air motor from the guide block (4) by removing the screws (3).
2 Pull back the compressed-air motor (5) in its fastener.
3 Place the required distance sleeve (7) on the milling cutter (6).
4 Move the torch with the gas nozzle (2) to the clamping position (P2).
5 Keep the guide block (4) in the lower position (lift down).
6 Place the compressed-air motor (5) against the gas nozzle (2) with the distance sleeve placed on
top (7).
7 Fasten the adjusted motor position by means of the screws (3).
8 Move the torch out of the clamping device (1) and remove the distance sleeve (7) from the milling
cutter (6).
Gas nozzle
2
Setting up the clamping position
Clamping device
4
Gas nozzle
5
Screws
6
Setting up the compressed-air motor
1
2
3
Cleaning station BRS-LCi
3
1
2
7
3
6
5
4
Guide block
7
Compressed-air motor
Milling cutter
6 Putting into operation
Prism
Distance sleeve
EN - 9