Operation
1
Flushing and checking for leaks
IMPORTANT: After installation is complete, remove the
aerator from the faucet (A) to ush the water lines. Do not
lose the gasket (1) in the aerator.
□
Turn on the water supply and allow both hot
and cold water to run for at least one minute
each. Press the pin (2) to the bottom position,
and ush water lines for one minute. This
ushes away any debris that could cause
damage to internal parts. Check for leaks.
□
After ushing, turn the handle all the way
off to shut off the water and reinstall the
aerator. The pin should now be in its normal
position. Re-tighten any connections if
necessary, but do not overtighten.
Care and Cleaning
□
To clean, wipe down with a damp cloth and dry with a towel.
□
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
Troubleshooting
NOTE: Refer to the service parts section in this manual for
a detailed drawing showing the location of the parts listed
below.
Problem
There are leaks from the
handle.
The water will not shut off
completely.
Possible Cause
The bonnet nut has come loose and/or the
washer is dirty or damaged.
The cartridge is dirty or broken.
1
□
□
□
□
7
Please contact 1-855-HD-GLACIER for further assistance.
2
Solution
Tighten the bonnet nut.
Clean or replace the washer.
Remove the handle to check
the cartridge.
Clean or replace.