QUICK GUIDE
Cod. 970202b V11_20
NEO MEET MONITOR INSTALLATION
CONNECTIONS
Further information at meet.fermax.com
BASIC DIAGRAMS
PoE SWITCH IN BUILDING
SWITCH IN BUILDING. NO PoE
LAN PoE:
RJ 45 LAN connection.
+12V, -:
12 Vdc power supply for the cases where no
LAN PoE is available.
RS485+, RS485-, 12V:
RS485 connection for Ref.
1616 Module.
S:
12Vdc 100 mA alarm output.
(-):
Negative common (alarms input and output).
Z1-Z8:
Input alarms sensors (Z1-Z8).
NOTE: Z8 is reserved for tamper sensor.
Powered by PoE
Powered by 12 Vdc
Ref. 1616 connection
TERMINAL BASIC PROGRAMMING
Enter the basic configuration information:
- Block number
- Apartment number
- Monitor number (default "0")
- IP address
- Subnet mask
- Gateway
- DNS
Enter installer password
Default password: 6666.
PC BASIC PROGRAMMING
Use a PC with web browser (preferably Chrome)
Default IP: 10.1.1.1
NOTE:
The PC must have an IP of the same range as the IP of the
monitor
EXAMPLE: In the case that the IP of the panel is 10.1.1.1,
the IP of the PC must be of type 10.X.X.X with a subnet
mask 255.0.0.0
Enter the network basic information:
- IP address
- Mask
- Gateway
- DNS
To login, identify yourself with
the username and password.
Default value:
• Username: admin
• Password: 6666
Enter the installation basic information:
- Block number
- Apartment number
- Monitor number (default "0")