confirm the selection by pressing the "O/I" button. At this point, turn off the unit by pressing and holding the
"O/I" button for about 3 seconds.
DELETION OF STORED DATA
Deleting all data stored in a memory zone.
When the appliance is turned off recall your memory zone by pressing the "O/I" button for 3 seconds and then
the "M" key to select the memory zone and confirm by pressing the "O/I" button. Then switch off the unit,
holding down the "O/I" button for about 3 seconds. At this point, press the "M" key and then the "O/I" button for
about 3 seconds, the unit will emit a short beep and the display will show "---". Now all the data in the previously
selected memory zone will have been deleted.
MAINTENANCE
•
Store the device in its case in a well-ventilated and dry place without wrapping the hose too tightly and
without resting any heavy objects on top of it.
•
Clean the blood pressure monitor using a soft cloth, either dry or moistened with water and a liquid
disinfectant.
Never use chemicals or abrasives.
NEVER wash the cuff in the washing machine and do not rub it vigorously, but rather delicately wipe the
surface with a soft cloth, either dry or moistened with ethyl alcohol (75-90%) and leave it to dry naturally.
Do NOT press the "O/I" key if the cuff is not wrapped around the wrisf.
Do NOT disassemble the device.
•
It is recommended to check the performance of the device every 2 years or after repairs. Contact Laica
service assistance (activities excluded from the warranty).
TROUBLESHOOTING
Problem
Possible cause
After pressing the
The batteries have not been
"O/I" key the reading
inserted properly.
does not start.
The batteries are worn.
Solution
Check the correct positioning of the
batteries.
Replace them.
30
Problem
Possible cause
After pressing the
Strong electromagnetic interference.
"O/I" key the reading
does not start.
The display shows
The batteries are worn. If normal zinc-
the dead battery
carbon batteries are used, they will
symbol
.
need to be replaced more often
The readings are
The cuff is not correctly positioned.
very low or very
high.
Incorrect posture while taking the
reading.
During the reading, the person made
a movement or spoke, or the reading
was taken at a time when the person
was particularly anxious or nervous.
The heart rate
A movement was made during the
readings are too low
reading.
or too high.
The reading was taken after exercise.
An irregular heartbeat was detected
The
symbol
(arrhythmia).
appears on the
display.
The display reads
The blood pressure monitor was
"Err".
unable to detect the systolic or
diastolic pressure
English
EN
Solution
Remove the batteries for 5 minutes
and take the reading again.
Replace them. Use alkaline batteries
to increase operating autonomy.
Re-read the "Wrapping the cuff"
paragraph.
Re-read the "Proper reading method"
paragraph.
Re-read the "Proper reading method"
paragraph.
Repeat the reading, if the symbol
appears again, seek medical
advice.
Do not move during readings.
31