Pre-Use Checks - Scott Safety FH4 Instrucciones De Funcionamiento Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
SPECIFICATION
Protection Rating
PU stretch hose
PU non-stretch hose
EPDM hose
Visor Markings and Meanings (EN175:1997)
Symbol
Identification of the Manufacturer
SS
Scott Safety

PRE-USE CHECKS

Note The following instructions are for the FH4 headtop and breathing hoses.
These instructions must be used alongside the Operating and Maintenance
Instructions for the chosen PAPR.
HOSES
nspect the breathing hose for any
I
signs of creasing and ensure that it is
not torn
Ensure that both ends of the breathing
hose are free from dirt or debris and
that there is no damage to either ends
For a Tornado/Proflow hose check
that the 'O' ring is in place and in
good condition
Note 'O' rings and gaskets on all hoses
should be replaced at least annually.
EN12941:1998+A2:2008
T/Power
TH2
TH2
TH2
Symbol
B
HEADTOP & HELMET
Check that the headtop is in a good,
clean condition, free from any damage
and is not torn; paying attention to
the hose inlet, also the browband,
faceseal and head harness
Inspect the spatter guard for any signs
of damage, ensuring it is free from
deep scratches, cracks or crazing
Make sure that there are no blemishes,
solvents or paint that may obscure
vision
Ensure the spatter guard and welding
filter are correctly placed and secure
Make sure faceseal band is correctly
attached to locating tabs
11
Proflow
TH2
TH2
TH2
Impact Resistance
Medium Energy Impact
FH4