Transmission - Uptime Test
EN
1.
Connect both display and remote units to the network or cable under test
2.
Pair the remote unit with the display unit via
status connection will light up blue once successfully paired
Set the link speed to Auto in the display unit via Settings - Network - RJ45
3.
- Link Speed
4.
Set up bandwidth, frame size and test duration in Up Time Test
5.
Use default frame loss count 0 as Pass/Fail limit and save all changed
setup
Press Test key to run the test
6.
7.
Save the results
1
4
12
www.idealnetworks.net
2
5
Settings - Pairing. The
3
6