8.6 Fault-warning condition output signal
The s.s.c.i.e. shall have an output to transmit the fault-
warning condition specified in 8.2. The output signal shall
be given if the s.s.c.i.e. is de-energized.
Clause / Requirement
9 Disabled condition - Optional function
9.3 Indication of specific disablements
9.3. 1 Each emergency loudspeaker zone shall be indicated
by means of separate light-emitting indicators and/or an
alphanumeric display. The indications shall not be
suppressed during the voice-alarm condition.
9.3.3 The same light-emitting indicator may be used as that
for the indication of the corresponding fault, although the
indication shall be distinguishable. The same light-emitting
indicator and the same indication may be used to indicate a
disabled emergency loudspeaker zone and an emergency
loudspeaker zone under test.
Clause / Requirement
10 Test condition - Optional function
Clause / Requirement
11 Manual mode control - Optional function
11. 1 .2 In the manual mode, the receiving and display of
signals shall not be inhibited.
11. 1 .3 In the manual mode, any phased evacuation
sequence shall be halted. Returning the system to
automatic mode shall reinstate the phased evacuation
sequence as if it had not been halted.
Bosch Security Systems B.V.
The Praesideo network controller provides two predefined
control outputs for audible and visual fault indicators with
fail-safe behavior. When de-energized, the contacts of
these control outputs are closed (activated).
Compliance
The optional disablement condition is not supported by the
Praesideo system.
The optional disablement condition is not supported by the
Praesideo system.
Compliance
The optional test condition is not supported by the
Praesideo system.
Compliance
Praesideo does not inhibit the receiving and display of
signals in the manual mode.
Praesideo will resume manually overruled calls after the
overruling call has finished, providing that the overruled call
was without live speech and had emergency priority.