Connecting The Terminals - Commercial Electric 74208/HD Guía De Uso Y Cuidado

Panel plano cuandrado de 5-6 pulg. con temperaturas de color seleccionables
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5-6 In. Recessed Can Installation
1
Turning Off the Power
□ Turn the power OFF at the switch and
fusebox or the circuit breaker.
□ Remove the existing trim installed in the
recessed housing.
2
Choosing a color temperature
before installing
□ Use the slide switch to choose a color
temperature before installing. Soft White
(SW), Bright White (BW), Daylight (DL) or
choose to adjust the color temperature
from the wall switch (SWITCH) (See Fig. 1).
Fig. 1
Soft White
3000K
Bright White
4000K
Daylight
5000K
Switch*
3
Installing the adapter
□ Install the E26 adapter (DD) into the socket (See Fig. 2).
Fig. 2
4

Connecting the terminals

□ Connect the two terminals together (See Fig. 3)
Fig. 3
Connect the orange connectors
5
Adjusting the torsion springs
□ Insert the torsion springs into the fixture housing brackets
□ When installing trim into a 5 in. recessed housing, the torsion
spring (FF) must be moved. Unscrew the torsion spring (FF) from
the 6 in. position and move it to the 5 in. position (See Fig. 4).
Fig. 4
Move the torsion spring from the 6 in.
position to the 5 in. position
FF
6
Installing the fixture
□ Gently push the fixture into the recessed housing (See Fig. 5).
Fig. 5