THIS SYSTEM IS ONLY FOR USE WITH POTABLE WATER SOURCE THAT IS MICROBIO-
LOGICALLY OR CHEMICALLY SAFE.
NOTE: OUTDOOR INSTALLATION MAY REQUIRE ADDITIONAL COSTS. THIS IS DETER-
MINED BY AREAS WHERE SEVERE WEATHER CONDITION SUCH AS HURRICANES,
TORNADOES, EARTHQUAKES, FREEZING, ETC., CAN EXIST OR BASED ON LOCAL
ORDINANCES AND REGULATIONS, ETC. FINAL INSTALLATION DECISION WILL HAVE
TO BE MADE BETWEEN SYSTEM'S PURCHASER AND LICENSED INSTALLER. WE REC-
OMMEND THAT YOUR UNIT IS INSTALLED BY A LICENSED & INSURED PLUMBER.
READ AND FOLLOW THESE INSTRUCTIONS AND SAVE THIS MANUAL. WARRANTY
MAY BECOME NULL AND VOID IF ORIGINAL INSTALLATION IS NOT PERFORMED BY A
CERTIFIED LICENSED PLUMBER.
IF NEEDED ON ANY THREADED CONNECTIONS - DO NOT USE JOINT
COMPOUND/PIPE DOPE - USE TEFLON TAPE
IT IS IMPORTANT TO CUT PLASTIC TUBING STRAIGHT, NOT AT AN ANGLE. THIS WILL
INSURE A PROPER FIT AND AVOID LEAKAGE.
WH-750/500 SYSTEM INSTALLATION:
Installation of the Ultra Tech Water Filtration System must be installed by
STEP "A"
1. Remove your new Ultra Tech Water Filtration tank system and all the tubing from
shipping carton.
Remove white safety cap on top of tank.
Open small box and remove filtration valve.
Place bottom of white distributor cone over the center filtration tube and line up the valve
threads with the tank threads.
Turn valve clockwise (right) until tightly applied.
Choose the compatible size inlet and outlet adapters you will be using
(same size as main water line) 1/2", 3/4" or 1" included in the installation kit.
Remove fastening clips, install both adapters and replace the locking clips.
2. Turn the main water supply off.
Turn on nearest hose or faucet to release the water pressure to installation location.
3. Locate main water supply at point of entry to installation location.
Make two cuts (approximately six inches apart) in the main water line at point of installation.
4. Position your New Ultra Tech Water Filtration System next to the newly cut main water line.
Connect the quick connect elbow fitting to the bottom section of the main water line
(press down until you feel or hear a "click").
Measure out the tubing (from the filter shipping carton) and the necessary fittings
(2nd small box) and install this section to the left or inlet side of the valve (black handle).
Repeat this step to the top section (water flow into location) of the of the main water line.
Continue to measure out and install the tubing (from the filter shipping carton) and the
necessary fittings (2nd small box) to the right outlet side of the valve (red handle).
Fasten the four wall mount brackets (included in installation box) to the elbow fittings,
securely to the wall.
INSTALLATION INSTRUCTIONS:
a licensed plumber for the warranty to be valid.
3