Whirlpool AKR 749 WH Manual De Uso página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
INSTALLATION - ASSEMBLY INSTRUCTIONS
The instructions below, to be carried out in the order in which they are numbered, refer to the figures (with the same step numbers) given on the last pages of
this manual.
1.
Position the wall unit shelf at a height of 14 cm from the bottom
2-3-4. Position the drilling template on the bottom of the shelf, drill the 4 Ø 5mm side holes and prepare the central opening for the air vent
5.
Fit the check valve for fumes to the hood's fumes outlet
6.
Feed through the power supply cable and secure the cable clamp (using n.1 screw 3.5x9.5)
7.
For the upper outlet: drill the top of the wall unit, taking into account the position of the outlet hole
8.
For rear outlet: drill the back of the wall unit at the desired height
9.
Secure the hood to the wall unit using the 4 screws 4.2x35
10.
Open the steam deflector and remove the metal grease filters
11.
Adjust the slideout stroke of the deflector by installing the two brackets provided; fix them using the 2 screws 3.5x9.5
12-13. Fit ducting for the venting of fumes, connecting it to the connector ring (for the Filter version, a small section of ducting that reaches the top of the
wall unit will suffice)
NB: the ducting is not included in the pack and must be purchased separately
14.
For filter version only: fit the carbon filter (refer to instructions in the section MAINTENANCE-Carbon Filter)
15.
Refit the metal grease filters
GB13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Akr 749 ix

Tabla de contenido