K-8807
Strainer Plate
Body
Plumbers Putty
Gasket
Plate
Nut
Washer
Tailpiece
Nut
1. Install the Strainer
Apply a ring of plumbers putty to the underside edge of the
drain body flange or strainer body flange.
Insert the drain or strainer body in the sink.
For K-8807 model. Assemble a gasket, plate, and nut to the drain
body from under the sink.
For K-8813 and K-8814 models. Assemble the rubber washer,
friction washer, and locknut to the strainer body from under the
sink.
Wrench tighten.
NOTE: Do not reposition the drain after the locknut has been
tightened.
Align the wide end of the tailpiece with the drain or strainer
body, slide the nut onto the tailpiece, and thread the nut to the
drain or strainer body.
Position the trap on the end of the tailpiece.
If necessary, cut the tailpiece to ensure proper fit.
Kohler Co.
K-8813, K-8814
Basket Strainer
Strainer
Plumbers Putty
Rubber Washer
Friction Washer
Locknut
Washer
Tailpiece
Nut
3
112446-2-BC