Translation of the original instructions
2. To save energy, the fan will not work unless the under two situations:
The fan will work when the load is exceed 30% of the related power of the inverter;
When the inside temperature of the inverter exceed 60 degree, fan work.
3. About extended cable using:
We do not recommend use extended cable between the inverter and the battery, because it will case lost of DC electri-
city and affect the effect of the inverter.
If you must use an extension cable, we recommend using high quality cables with larger cross-sections to reduce the
risk of electrical losses.
CONNECTION
- Make sure that the input voltage of the converter corresponds to the battery voltage (12 V or 24 V).
- Until it is indicated to switch it on, the converter should remain switched off.
- Connect the converter to the battery with the cables supplied.
- Observe the following steps in order.
1. Connect the black cable to the negative terminal of the converter and then the red cable to the positive terminal of
the converter.
After each connection, replace the red and black plastic covers. They prevent the connections
from coming into contact with metal parts and causing a short circuit.
2. Connect the black cable to the negative terminal of the battery, and then connect the red cable to the positive
terminal of the battery.
Check the connection before the next step. Do not invert the connection as this may damage
the converter.
3. Set the switch to the «ON» position, the green light will come on, the product is ready for use. If the alarm goes
off, switch off the product and refer to the list of alerts.
DISCONNECTION
To disconnect the converter, follow the steps below in order:
1. Disconnect the red terminal from the battery terminals, then the black terminal.
2. Disconnect the red cable from the positive terminal of the converter, then the black cable from the negative terminal
of the converter.
Once each cable has been disconnected, replace the red and black plastic covers on the convert-
er connectors.

REMOTE CONTROL

PSW 601 W
PSW 1002 W / 1502 W / 2002 W
1
PSW 601 W / 1002 W / 1502 W - 12 V /
2002 W - 12 V / 2002 W - 24 V
1
2
2
Input display
EN
press
Output display