Installation
1. Ensure your product comes with the items indicated on page 4; if not please contact
your dealer.
2. Drill a 1 ⁄ 2" or 13mm diameter hole for the tamper magnet — see page 4.
3. Push the tamper plug into the hole, then insert the tamper magnet.
4. Drill a 13 ⁄ 32" or 10mm diameter hole for the flying lead — see page 4.
5. Connect the flying lead — see page 5.
6. Set output format — see page 6.
7. Configure reader — see page 9.
8. Use the supplied vandal resistant screws to attach the reader to the wall. These require
a special screwdriver (P/N 1950), available separately.
9. Apply power when all readers are installed.
Notes
•
If power is applied when the tamper magnet is not positioned correctly, a reader
tamper condition is generated and the reader beeps.
•
Mount readers >3' / 1m apart, e.g. on either side of the door. Mounting on metal
surfaces will reduce the reading range.
•
If the reader is being used to enter credential information to arm a system, the
reader must be located within 3' / 1m of the panel's main keypad or display.
•
For outside readers, use corrosion-resistant fixings and apply silicone sealant to
the backplate before fixing to the wall.
•
The supplied MOV (Metal Oxide Varistor, Anglia Components P/N B72207S250K101)
should be fitted across the power terminals of the lock to suppress back EMF. Any
suppression diodes fitted in the lock / lock circuit must be removed.
•
Output format and reader configuration can be changed without disconnecting the
power supply. The reader automatically restarts with the new configuration.